4.4 SPEED and SLOW DOWN OF THE MOTOR
This operation can ad just fast the speed of
the motor when opening and closing and the
slow down.
Set up
Description
Values
Standard
Value
L 01
Standard speed
MOT1
from 1 to 10
10
L 02
Speed of slow down
MOT1
from 1 to 10
5
L 03
Standard speed
mOT2
from 1 to 10
10
L 04
Speed of slow down
mOT2
from 1 to 10
5
4.5 Level of the MOTOR
This operation can ad just the obstacle
detection.
Look on the table.
Set up
Description
Values
Standard
Value
L 05
Level of obstacle
detection or LS mOT1
from 1 to 10
(0 = deactivation)
5
L 06
Level of obstacle
detection o LS mOT2
from 1 to 10
(0 = deactivation)
5
L 07
Level of obstacle
detection o LS mOT1
in case of slow downfrom
from 1 to 10
(0 = deactivation)
5
L 08
Level of obstacle
detection o LS mOT2
in case of slow downfrom
from 1 to 10
(0 = deactivation)
5
14
4.6 Logic of OBSTACLE DETECTION
If you use
S20
you can set up the obstacle detection:
Set up
Description
Values
S 20
Logic of
obstacle detection
1
LIMIT SWITCH FUNCTION
(standard function)
2
STOP function
3
STOP function but before it
reverse the move of the mo
-
tors for 2 seconds
make this operation
before the memorization
of the working time.
WARNINg
Use the set up 2 and 3 only in
case the limit switch is available.
1 = Very sensitive
5 = medium sensitive
10 = Low sensitive
If the functions
L05
and
L06
are on
“0”
, the control unit will be dama
-
ged if the motors will stop for just
one second.
Summary of Contents for START S10
Page 21: ...NOTE 21 ...
Page 22: ...NOTE 22 ...
Page 45: ...NOTE 21 ...
Page 46: ...NOTE 22 ...
Page 67: ...NOTE 19 ...
Page 89: ...NOTE 21 ...
Page 90: ...NOTE 22 ...
Page 113: ...NOTE 21 ...
Page 114: ...NOTE 22 ...