background image

 

Important notes

The manufacturer may change the product without warning: also the manufacture declines all responability for 

the inadvertent or negligent operation when the product is not installed as per the instructions in the manual. 

Please observe the following instructions, they provide you with important information on the safe installation.

•  This manual is only for qualified installers in the automation field.

•  Any installation, maintenance or programming must only be carried out by qualified installers, as any change 

or reconfiguration of the product without consulting the manufacturer or the agent can be dangerous.

This device conforms to the Norm EN 954-1 category 2 only if used in the active TEST configuration DIP1 TX 

& RX OFF.

Check that the CE marking can be clearly read, it is also labelled with: production lot, nominal voltage, nominal 

current and IP rating.

It is important that the end user is informed about:

•   Replacing the battery every 12 months to guarantee the correct operation, testing the complete installation 

after replacing.

•  Before closing the TX, make sure the O-RING is undamaged and clean. If necessary remove any dust with 

a cloth. Contact eB technology for any spare part.

•  The access area where the device is installed must be free from obstacles.

It is necessary to install a fuse in-line with the output of the relay, with value v ≤ 100 mA and power ≥ 60 V.

All users must be made aware of the safety devices in use

 

Installation and maitenance

 

Intended use

TX

N.C.  /  8,2k

TX

TX

RX

Application on sliding automation

TX

RX

Application on rapid doors

Typical applications are:

• Weirs and bulkhead

• Lift doors

• Vehicle door

• Doors for cases

• Curtains for theater, rail barriers

• Barriers only for vehicles. Safety devices for machines differ from doors

This device cannot be be used for manual control or for stop system, even emergency, of motorized doors.

The product can be installed for sliding gates and industrial-sectional doors. The maximum speed of the instal-

lation is 60m/min, as the time response is 100ms.

-9-

Summary of Contents for TX-MINI

Page 1: ...X regeln 868 Mhz radio bidirectional device wireless which transmits a signal to a control device The receiver constantly checks the status of the transmitters connected to it It can manages up to 16...

Page 2: ...per garantire sempre il corretto funzionamento veri care dopo la sostituzione le funzionalit del sistema Prima della chiusura del contenitore del modulo TX accertarsi che guarnizione e sede relativa s...

Page 3: ...lle caratteristiche EMC dell intero impianto necessaria Il seguente prodotto risponde alle normative vigenti solo se collegato con TEST Dichiarazione CE conformit Caratteristiche tecniche Dimensioni b...

Page 4: ...2 3 4 JUMPER N R NA NC 1 2 3 4 5 6 7 8 9 12 24 Vac dc 12 24 Vac dc OUT N R 1 OUT N R 2 COM TEST TEST T1 TEST T2 9 ING 2 COSTA ON P1 LED TX1 P2 P1 PROG P2 CHECK BUZZER LED OUT1 N R1 N R2 ON LED OUT2 L...

Page 5: ...ne Ricevitore Reset della memoria del ricevitore Questa operazione deve essere effettuata sempre al primo utilizzo Trasmettitore 4 Collegare nei morsetti del TX il contatto di sicurezza NC oppure il c...

Page 6: ...si 3 segnali acustici 4 Una volta effettuata la memorizzazione il ricevitore esce automaticamente dalla modalit di apprendimento e il LED RX1 si spegne Per memorizzare un altro TX sullo stesso ingress...

Page 7: ...azione Se si sceglie di operare con questa con gurazione si consiglia di eseguire l installazione con DIP 1 OFF sia su TX che RX in modo da eseguire il test di funzionamento con il sistema CHECK e poi...

Page 8: ...3 beep veloci se ha rilevato problemi Durante il modo CHECK l utilizzatore potr eseguire comunque le manovre dell automazione Segnalazione Batteria Scarica Il Ricevitore emette 3 brevi beep se il TX c...

Page 9: ...rmed about Replacing the battery every 12 months to guarantee the correct operation testing the complete installation after replacing Before closing the TX make sure the O RING is undamaged and clean...

Page 10: ...tallation is necessary This product complies with the current norms only if it connected with TEST EC declaration of con rmity Technical features Dimensions b65 x h81 x d30 mm Power supply 12 24 Vac d...

Page 11: ...NA ANTENNA DIP 2 IN 1 OFF NC contact ON 8 2K contact DIP 3 IN 2 OFF NC contact ON 8 2K contact 12 Vac dc 24 Vac dc RX ANTENNA ANTENNA JUMPER J12 8 7 1 2 3 4 JUMPER N R NO NC 1 2 3 4 5 6 7 8 9 12 24 Va...

Page 12: ...all previously memorized installations First Installation Receiver Cancel of the memory of the receiver This operation should be done at the rst installation Transmitter 4 Connect to the terminal boa...

Page 13: ...lready memorized the buzzer beeps three times 4 Once the memorization has been completed the receiver works automatically and the LED RX1 turns off If you need to memorize extra transmitters start fro...

Page 14: ...signal from the transmitter the RECEIVER switches on the alarm output for the corresponding TX Installation To test this operating mode put DIP 1 OFF in the transmitter and in the receiver after compl...

Page 15: ...s out of the CHECK operation the receiver will give one long beep if the transmission with the TX is correct while it will beep 3 times if there is a problem with the tx During the CHECK operation the...

Page 16: ...t cr er des situations dangereuses Le dispositif r pond aux normes requises EN 954 1 cat gorie 2 SEULEMENT si on utilise la con guration TEST avec contr le active DIP1 TX RX OFF Il faut v ri er que le...

Page 17: ...cessaire de contr ler les caract ristiques EMC de l installation Le produit correspond aux normes actuelles s il est branch avec TEST D claration CE de conformit Caract ristiques techniques Dimension...

Page 18: ...t NC ON contact 8 2K 12 Vac dc 24 Vac dc RX ANTENNE ANTENNE JUMPER J12 8 7 1 2 3 4 JUMPER N R NA NC 1 2 3 4 5 6 7 8 9 12 24 Vac dc 12 24 Vac dc OUT N R 1 OUT N R 2 COM TEST TEST T1 TEST T2 9 ON COM PA...

Page 19: ...tteur est effac e Premi re installation R cepteur Effacer la m moire du r cepteur Cette op ration doit tre effectu e toujours la premi re utilisation Emetteur 4 Connecter aux bornes de TX le contact d...

Page 20: ...tteur a t m moris correctement si l metteur a t d j m moris le buzzer sonne trois fois 4 Le r cepteur sort de la programmation automatiquement et LED RX1 s teint Pour m moriser un autre metteur il fau...

Page 21: ...X le r cepteur met en alarme le TX Installation Si vous choisissez d utiliser avec cette con guration il est recommand de placer DIP 1 OFF de TX de RX de mani re effectuer la fonction de test avec le...

Page 22: ...omalies Au terme de la v ri cation du contr le il est possible de faire des manoeuvres Indications batteries faibles Le receiver met bips sonores si la pile du TX est able Pour la con guration avec le...

Page 23: ...eses Produkt entspricht den wesentlichen Sicherheitsanforderungen der folgenden weiteren Richtlinien Kat 2 EN 954 1 nur im Test Kon guration mit aktiver Kontrolle DIP 1 TX RX OFF Pr fen die lesbare CE...

Page 24: ...ist notwendig die Kontrolle der EMC Beschreibungen Diese Produkt etnspricht die gesetzliche Richtlinien nur wenn mit Funktion TEST verwendet wird EG Konformitatserklarung Technische Merkmale Abmessug...

Page 25: ...ATTERIE ANTENNE ANTENNE DIP 2 Eingang Nr 1 OFF n geschlossen Kontakt ON 8 2K Kontakt DIP 3 Eingang Nr 2 OFF n geschlossen Kontakt ON 8 2K Kontakt 12 Vac dc 24 Vac dc RX ANTENNE ANTENNE JUMPER J12 8 7...

Page 26: ...ht Erste Installation Empf nger Den Speicher des Senders l schen Dies sollte bei der ersten Installation gemacht werden Funksender 4 Verbinden Sie den N C Kontakt oder den 8 2 K Widerstandsendkontakt...

Page 27: ...der Summer drei Mal 4 Wenn die Programmierung fertig ist schaltet das Funkempf nger sofort aus und LED RX1 schaltet sich aus Um ein neuen Sender zu programmieren fangen Sie wieder von Punkt 1 an Um d...

Page 28: ...ekunden Wenn der Empf nger nach 30 Sekunden kein Signal vom Sender erh lt bringt der Empf nger eine Warnmeldung in den Ausgang des entsprechenden TX Installation Wenn Sie sich f r diese Bedienungsinst...

Page 29: ...ertragung des TX anzuzeigen Wenn der Empf nger nicht mehr im Check Vorgang ist piept er ber einen l ngeren Zeitraum Sollte es Probleme mit dem TX geben piept der Empf nger dreimal W hrend des Check Vo...

Page 30: ...instrumento y consultar siempre que haya duda sobre el uso y leerlo a la hora de hacer el mantenimiento Este dispositivo est conforme a las normas de la unidad Europea EN 954 1 con el TEST activo DIP1...

Page 31: ...er sticas EMC pueden variar seg n el tipo de instalaci n entonces es necesario averiguar las caracter sticas EMC de toda la instalaci n El producto siguente responde a la norma solamente si est conect...

Page 32: ...AD ENTRADA 1 BANDA DE SEGURIDAD BATERIA BATERIA ANTENNA ANTENNA DIP 2 Entrada 1 OFF contacto NC ON contacto 8 2K DIP 3 Entrada 2 OFF contacto NC ON contacto 8 2K 12 Vac dc 24 Vac dc RX ANTENA ANTENA J...

Page 33: ...elada Primera Instalacion Receptor Borrar la memoria del receptor Esta operaci n debe ser efectuada siempre a la primera utilizaci n Trasmisor 4 Conectar en las terminales del Tx el contacto de seguri...

Page 34: ...3 se ales ac sticas 4 Une vez efectuada la memorizaci n el receptor saldr en autom tico de la modalidad de Grabacion y el LED RX1 se apaga Para memorizar otro TX en el mismo acceso comenzar del punto...

Page 35: ...con guraci n se veri ca un control activo de la seguridad y del sistema segun normativa la recepci n de la se al del transmisor TX est siempre activa y abr un consumo mayor de bater a En el caso de 2...

Page 36: ...itidos consecutivos si falta cobertura En modalidad CHECK se puede hacer manobrias en el automatismo Bateria descargada El receptor emite 3 senales acusticas si el TX tiene una bater a descargada si e...