Important notes
The manufacturer may change the product without warning: also the manufacture declines all responability for
the inadvertent or negligent operation when the product is not installed as per the instructions in the manual.
Please observe the following instructions, they provide you with important information on the safe installation.
• This manual is only for qualified installers in the automation field.
• Any installation, maintenance or programming must only be carried out by qualified installers, as any change
or reconfiguration of the product without consulting the manufacturer or the agent can be dangerous.
This device conforms to the Norm EN 954-1 category 2 only if used in the active TEST configuration DIP1 TX
& RX OFF.
Check that the CE marking can be clearly read, it is also labelled with: production lot, nominal voltage, nominal
current and IP rating.
It is important that the end user is informed about:
• Replacing the battery every 12 months to guarantee the correct operation, testing the complete installation
after replacing.
• Before closing the TX, make sure the O-RING is undamaged and clean. If necessary remove any dust with
a cloth. Contact eB technology for any spare part.
• The access area where the device is installed must be free from obstacles.
It is necessary to install a fuse in-line with the output of the relay, with value v ≤ 100 mA and power ≥ 60 V.
All users must be made aware of the safety devices in use
Installation and maitenance
Intended use
TX
N.C. / 8,2k
TX
TX
RX
Application on sliding automation
TX
RX
Application on rapid doors
Typical applications are:
• Weirs and bulkhead
• Lift doors
• Vehicle door
• Doors for cases
• Curtains for theater, rail barriers
• Barriers only for vehicles. Safety devices for machines differ from doors
This device cannot be be used for manual control or for stop system, even emergency, of motorized doors.
The product can be installed for sliding gates and industrial-sectional doors. The maximum speed of the instal-
lation is 60m/min, as the time response is 100ms.
-9-