background image

 

 
 
 

CD425 OWNERS MANUAL 

Drawing No.  :-  TPC252 
Issue :- 

Date :- 

13/10/03

 

REPAIRS 

 
 

 

1. 

Should an electrical component fail, consult the Factory Service Center to obtain the  

  proper 

replacement 

part. 

 
 

 

 

2. 

If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration  

 

 

technician to correct the fault.  Contact the Factory Service Center prior to initiating  

 

 

this action.  

 

 

 

Any competent refrigeration technician will be able to service the equipment.  The 
following procedure must be used: 

 
 

 

a.  The source of the leak must be determined and corrected. 

 
 

 

b.  The machine should be thoroughly evacuated before recharging. 

 

 

 

 

c.  The unit must be recharged with refrigerant measured accurately by weight. 

 
 

 

d.  For evacuation and recharging of the machine, use the crimped and brazed 

charging stub attached to the side of the refrigerant compressor. 

 

 

 

 

The charging stub should be crimped and rebrazed after servicing.  

N

EVER

 

allow 

permanent service valves to be fitted to any part of the circuit.  Service valves 
may leak causing further loss of refrigerant gas. 

 

 

 

 

3.  The refrigerant compressor fitted to the dehumidifier is a durable unit that should 

give many years of service.  Compressor failure can result from the machine losing its 
refrigerant gas.  The compressor can be replaced by a competent refrigeration 
technician.   

 
 

 

Failure of the compressor can be confirmed by the following procedure: 

 
 

 

a.  Establish that power is present at the compressor terminals using a voltmeter. 

 

 

 

b.  With the power disconnected, check the continuity of the internal winding by 

using meter across the compressor terminals.  An open circuit indicates that the 
compressor should be replaced. 

 

 

 

c.  Check that the compressor is not grounded by establishing that a circuit does not 

exist between the compressor terminals and the shell of the compressor. 

Summary of Contents for CD425

Page 1: ...2 Issue 1 Date 13 10 03 EBAC MODEL CD425 1018110 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products Inc 700 Thimble Shoals Blvd Suite 109 Newport News VA 23606 2575 Tel 757 873 6800 Fax 7...

Page 2: ...drain tray for collecting and disposing of condensed moisture f A cabinet to house the above components The fan draws the moist air through the evaporator coils which cools the air below its dew poin...

Page 3: ...1 Date 13 10 03 SPECIFICATIONS MODEL CD425 HEIGHT 1190 mm WIDTH 1100 mm DEPTH 460 mm WEIGHT 160 kg AIRFLOW 1750 CFM 3000M Hr TOTAL POWER 6 0Kw MAX MAXIMUM OPERATING TEMPERATURE 35 C 95 F POWER SUPPLY...

Page 4: ...Remove the front cover b Check the actual relative humidity inside the area c Set humidity control to a LOWER value than the actual relative humidity d After approximately 6 minutes check the compres...

Page 5: ...ng and flooding of the chamber WIRING Connect a suitably fused 3 phase mains power supply to the MAINS T B terminal block inside the electrical box located at the control panel end of the machine DRAI...

Page 6: ...for life and therefore does not need oiling 3 To check the refrigerant charge run the unit for 15 minutes and briefly remove the cover The evaporator coil should be evenly frost coated across its surf...

Page 7: ...of the refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak cau...

Page 8: ...breaker Little or no water extraction 1 Insufficient air movement 2 Compressor fault 3 Loss of refrigerant gas 4 Blocked filter dryer 1 Check all of the above 2 Contact the Factory Service Center 3 C...

Page 9: ...5kg Drain Tube 2014315 3 meters 3 8 Copper Tube 3014203 2 meters 1 2 Copper Tube 3014204 2 meters 5 8 Copper Tube 3014205 2 meters Cork Tape 3100223 1 2 Roll Fan Motor 3030140 1 Axial Fan 3010119 1 So...

Page 10: ...ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THE FOREGOING DESCRIBED MERCHANDISE For Your Records Model ____________________ S N ______________________ Date Received ______________ SAVE THIS SECTI...

Reviews: