background image

 

 
 

SD100/SD200 OWNERS MANUAL 

Drawing No.  :-  TPC210 
Issue :- 

Date :- 

22/06/05

 
 
 
 
 
 
 
 
 

 

EBAC MODEL SD100/SD200 

INDUSTRIAL DEHUMIDIFIER 

OWNER’S MANUAL

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

Ebac Industrial Products, Inc. 

700 Thimble Shoals Blvd, Suite 109 

Newport News, VA. 23606-2575 

Tel: (757) 873 6800 Fax: (757) 873 3632  

Website www.ebacusa.com 

Summary of Contents for SD100

Page 1: ...PC210 Issue 3 Date 22 06 05 EBAC MODEL SD100 SD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products Inc 700 Thimble Shoals Blvd Suite 109 Newport News VA 23606 2575 Tel 757 873 6800 Fax...

Page 2: ...fan draws the moist air through the cold evaporator coil which cools the air below its dew point Moisture forms on the evaporator coil and is collected in the condensate try which is equipped with a p...

Page 3: ...Ebac SD 100 Ebac SD200 HEIGHT 18 7 18 7 WIDTH 26 26 DEPTH 26 26 WEIGHT 143 lbs 172 lbs AIRFLOW Low 560 CFM High 760 CFM Low 560 CFM High 650 CFM HORSEPOWER 1 2 POWER SUPPLY 110V 115V 60Hz 1ph 208V 23...

Page 4: ...humidifier unit in the center of the room to be conditioned if at all possible However if a damp patch is particularly apparent the outlet grille should be pointed towards it NOTE Both inlet grille an...

Page 5: ...rill to confirm frost formation i If the air temperature is below 70 F an even coating of frost should cover the entire evaporator coil except for the last one or two coils ii If the air temperature i...

Page 6: ...clean the coils WARNING DO NOT STEAM CLEAN REFRIGERATION COILS 2 Check that the fan is firmly secured to the motor shaft and that the fan rotates freely The fan motor is sealed for life and therefore...

Page 7: ...ide of the refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak...

Page 8: ...r reset the circuit breaker Little or no water extraction 1 Insufficient air flow 2 Compressor fault 3 Loss of refrigerant gas 1 Check all of the above 2 Contact the Factory Service Center 3 Contact t...

Page 9: ...ING PLATE INFORMATION SD100 SD200 MOISTURE REMOVAL 2 5 Liters hr 4 2 Liters Hr REFRIGERANT 1120 Grams 1650 Grams VOLTAGE 115 Volts 208 230 Volts WATT 1100 2100 PHASE Single Single HZ 60 Hz 60 Hz 9 2 A...

Page 10: ...026870 1026870 Drain Tray 1 2811001 2811001 Evaporator Coil 1 3820707 3820708 Condenser Coil 1 3820705 3820706 Fan Blade 1 3840404 3840404 Fan Motor 1 3830112 3830109 Humidistat Terminal Block 1 N A N...

Page 11: ...OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THE FOREGOING DESCRIBED MERCHANDISE For Your Records Model ____________________ S N ______________________ Date Received ______________ SAVE THIS SE...

Reviews: