17
EBARA
PUMPS AMERICAS CORPORATION
www.pumpsebara.com
(t) 803.327.5005
(f) 803.327.5097
rev. 03/22
End Suction Centrifugal
GS Series
MOTOR
Fault
Causes
Measures to be taken
-
Fault in installation.
-
Check installation.
-
Bearings damaged.
-
Replace the bearings.
-
Flow rate too high.
-
Reduce the aperture of the
delivery valve.
-
Flow rate too low.
-
Increase the aperture of the
delivery valve.
-
Impeller is blocked.
-
Remove foreign bodies.
-
The direction of rotation is not
correct.
-
Check and correct the
connection.
-
Friction in the rotation areas. The
shaft is bent.
-
Repair in specialist workshop.
-
Cavitation.
-
Seek expert advice.
-
Vibrations in the piping.
-
Reinforce the piping or fit an
inverter
-
Defective fitting of the mechanical
seal.
-
Fit it correctly.
-
The mechanical seal is damaged.
-
Replace the mechanical seal.
-
Overpressure in delivery.
-
Review the project.
-
The shaft is bent.
-
Repair in specialist workshop.
Excessive water leakage
from the shaft seal.
Excessive operating
vibration and noise.
Fault
Causes
Measures to be taken
-
The winding is broken or has
been cut.
-
Repair in specialist workshop.
-
Stator short-circuited.
-
Repair in specialist workshop.
-
Grounded.
-
Repair in specialist workshop.
-
The bearings are blocked.
-
Repair the bearings.
-
The voltage is low.
-
Change the nominal voltage.
-
Loss of phases in the power
supply.
-
Check the power supply.
Motor does not start