12
Install with Cable Clip
The heating cable is recommended to be attached with Cable Clip 5 (89 609 59) for 6 mm reinforcing mesh. Follow
the instructions in general.
3. Pull out the first length of cable and secure it with tape/
glue at the markings.
4. This is how the cable is to be run and taped/glued around
floor drains and similar objects. Leave space for the floor
drain grille. NB! At least 20 cm distance between drain and
heating cable!
The cable may not be installed under fixed furnishings, such
as toilet bowls. It can be advantageous to secure toilet bowls
with silicon instead of screws.
Cable Clip 5
c/c
2
c/c
2
Min.
20 cm
2. Mark the c/c dimensions of the heating cable. Distance to the
wall must be the loop’s c/c dimensions divided by two.
1. Ensure that the floor is firmly in place, without sagging and
free from dirt and old floor coverings. Coat the floor surface
with Ebeco (89 605 50) and let it dry.
Prepare the subfloor
c/c
2
c/c
2
Embedding in concrete slab