12 / 24 VDC
Power Output
12 VDC
Setting
24 VDC
Setting
12 / 24 VDC
Power Input
N.C
C
+
-
N.O
Hall Effect Sensor
Output
(Only for LED Models)
Hall Effect
Sensor Input
(Only for LED
Models)
LED Status:
> Green = Locked
> Red = Released
> Off = No Input
(Only for LED Models)
12/24 VDC
Power
Self-tapping Screw
Mounting Plate
Cable Wire
Armature Plate
Sexnut Bolt
Rubber
Washer
Metal
Washer
Armature
Screw
Fixing
Screw
Anti Tamper
Nut
PCB Cover
Cover
Screw
Guide Pin
Allen Wrench
General Installation Steps & Maintainance
1.
2.
Close the door & position the template at the lock jamb side of the frame with a gap 10mm.
3. Mark & drill holes according to template indications.
4. Install the Armature Plate to the door.
5. Loosely tighten screw through the adjustable slot on mounting plate to the door frame as indicated on
installation template.
6. Make sure the mounting plate & armature align properly, then screw in the balance mounting screws.
7.
Use allen wrench to unscrew anti tamper nut and install the lock by tighten the fixing screws on the
mounting plate. Pull cable wire through frame to lock housing.
8. Screw in the anti-tamper nuts to prevent unauthorized access and make sure to fully tighten the fixing
screw with proper tool "T" Handle Allen Key.
9. Connect the power wires accordance with NFPA 101 & all wiring to be completed inside protect area.
10. Typical wiring method which shall be in accordance with CSA C22.1, Canadian Electrical Code, Part I,
Safety Standard for Electrical Installations, Section 32.
11. It is recommended that to apply a light coat of silicon lubricant to the mating surface on a monthly
basis to prevent rust.
Trouble Shooting
1.
Sensor not functioning
- Improper attachment of electromagnet and
armature plate
- Modification of the PCB
2. Door not locked
- Incorrect wiring or no power from power supply
3. Reduced holding force
- Poor contact of electromagnet and armature.
- Be sure armature is loose enough that it can fully
contact electromagnet along the entire length.
- Mating surface is dusty or damaged.
- Improper input voltage or wire size.
Performance Level
- Destructive Attack: Level I
- Line Security: Level I
- Standby Power: Level I
- Endurance 250,000 Cycles: Level IV
(Relay Source #2 & #3)
1-2
T Handle Allen Key
(Not include in package)
Electromagnetic Lock
Installation Instruction Guide
(Intend for use in indoor dry location)
Set the jumper position according to the power
input correctly before switch ON the power.
Caution Against Changing
Factory Applied Settings !
Out Swing
EM Lock
Door
Frame
General Installation
Door Frame
Out-Swing
Glass
Door
EM Lock
Door
U1 Bracket For
Glass Door
Door
Out-Swing
EM Lock
Door
Frame
ZL Bracket For
In-Swing Door
LS Bracket For
Out-Swing Door
Door
Frame
Door
EM Lock
Self-tapping Screw
In-Swing
AH Bracket Fire Door Application
Out Swing
Door
Frame
Door
EM Lock
Armature Plate
Armature
Housing
DSU Bracket For
Glass Frame & Glass Door
EM Lock
In-Swing
Glass
Door
Glass
Frame
Spec
Model
Voltage Input
12VDC / 24VDC
Dimension
(L)250 x (W)42 x (T)25 (mm)
Current Draw
12VDC / 24VDC
(L)266 x (W)67 x (T)39 (mm)
(L)210 x (W)35 x (T)22 (mm)
300-LED
600-S
600-LED
1200-S
1200-LED
12VDC / 24VDC
*
12VDC / 24VDC
(L)250 x (W)50 x (T)29 (mm)
800-S
800-LED
*
*
Static Strength
Dynamic Strength
N/A
N/A
50ft-lb
70ft-lb
Basic Installation Concept & Accessories
600lbs (Factory Tested)**
500lbs (UL Verified)
1200lbs (Factory Tested)**
1000lbs (UL Verified)
Up to 600lbs
(Factory Tested)**
Up to 300lbs
(Factory Tested)**
330mA / 185mA
480mA / 240mA
510mA / 285mA
480mA / 240mA
510mA / 285mA
420mA / 210mA
500mA / 265mA
EISB-EMS-IG Ver.A Publish:11.3.2020
Notice:
All models are Recognized to:
UL 294 and ULC S533-15 : Standard for Access & Egress.
* Models are not listed in UL 1034
* * Value not verified by UL.
UL 1034, Standard for Burglary-Resistant Electric Locking Mechanism.
UL 294, Access Control System Units
Remark: All drawing shown are for illustration purpose only.
Actual product may vary due to product enhancement.
Models 800-S, 800-LED, 1200-S & 1200-LED are listed to: