Membrane cleaning brush

Always turn off the device and disconnect it from the power supply before cleaning. Do not touch the 

water in the base! The small amount of water in the base of the device is a natural effect resulting from the 

design and specification of the device. 

Clean the water tank regularly with clean water and a soft, damp cloth. Do not use detergents, alcohol, or 

other chemical and corrosive substances. Do not use hard brushes. Allow it to dry before restarting the 

device. Do not install the nozzle column in the tank until these components are completely dry. 

A special brush with a humidifier should be used to clean the steam-generating membrane. The membrane 

is located under the descaling filter. The brush is located in a special place in the base of the humidifier. 

• 

The device is equipped with a descaling filter. It is located in the center of the humidifier base.  

• 

To replace the filter, lift the water tank by detaching it from the base of the humidifier. Perform this 

operation with extreme caution and pay special attention not to spill the water from the tank or 

replace the filter when the water tank is empty. 

• 

Pull the used filter out of the center of the humidifier base.  

• 

Put the new filter in the same place. 

• 

Place the water tank back in place. 

Attention!

The device is originally equipped with one descaling filter. The replacement filter must be purchased 

separately. 

VI. CLEANING AND MAINTENANCE  

Descaling filter

Descaling filter

Summary of Contents for EDO

Page 1: ...ULTRAD WI KOWY NAWIL ACZ POWIETRZA ULTRASONIC HUMIDIFIER EDO Instrukcja obs ugi Instruction manual...

Page 2: ...w a ciwe wykonanie napraw mo e spowodowa znaczne zagro enie dla u ytkownika Ustawi nawil acz na suchej wypoziomowanej powierzchni w pozycji pionowej Nie umieszcza urz dzenia bezpo rednio na pod odze l...

Page 3: ...w wodzie lub innym p ynie nale y natychmiast od czy je od zasilania W takiej sytuacji urz dzenie musi zosta sprawdzone przez autoryzowany serwis przed ponownym uruchomieniem Nie wlewa olejk w eteryczn...

Page 4: ...zbiornika Kolumna wylotu pary Zbiornik na wod Wska nik poziomu wody Odkraplacz Rdze pokrywy zbiornika Spr yna P ywak Szczoteczka do czyszczenia Korek zbiornika wody Zbiornik do aromaterapii D wignia...

Page 5: ...1 12h Ka de naci ni cie przycisku zmienia nastaw o 1h Poziom nawil ania Urz dzenie pozwala na ustawienie po danego poziomu nawil ania obj to mgie ki wylatuj cej przez dysz S dost pne 3 poziomy nawil...

Page 6: ...ej si w podstawie Nie wlewa wody do dyszy wylotu pary w urz dzeniu Uwaga Nie wlewa do zbiornika na wod adnych olejk w zapachowych Olejki zapachowe mog by dodawane jedynie do specjalnej tacy umiejscowi...

Page 7: ...embrany generuj cej par nale y u ywa specjalnej szczoteczki w kt r wyposa ony jest nawil acz Membrana znajduje si pod filtrem odkamieniaj cym Szczoteczka znajduje si w specjalnym miejscu w podstawie n...

Page 8: ...um 12h Nast pnie wlej czysta wod Z dyszy wydostaje si bardzo ma a ilo pary Membrana ceramiczna jest zabrudzona lub w zbiorniku znajduje si brudna woda Wyczy membran ceramiczn i wymie wod na czyst Zbyt...

Page 9: ...to the ventilation openings The device should be placed in an elevating position e g on a table drawer etc If the mist coming out of the humidifier comes into contact with the floor before evaporatin...

Page 10: ...and similar additives directly into the water tank The use of water additives damages the material of the tank and consequently the entire device Essential oils can only be used in a special aroma co...

Page 11: ...k cover Bottom water tank cover Mist output column Water tank Water level window Filling water Droplet eliminator Tank cover core stick Spring Float Cleaning brush Float plug Aroma container Float lev...

Page 12: ...f humidification the volume of the mist flowing out through the nozzle There are 3 levels of humidification 1 2 3 Use the button to set the humidification level on both the control panel and the remot...

Page 13: ...e Attention Do not put any fragrance oils into the water tank Fragrance oils can only be added to a special tray located in the base of the humidifier Fragrance oils added directly to the water tank m...

Page 14: ...ldbeusedtocleanthesteam generatingmembrane Themembrane is located under the descaling filter The brush is located in a special place in the base of the humidifier The device is equipped with a descali...

Page 15: ...imum of 12 hours Then pour in clean water Very little steam comes out of the nozzle The ceramic membrane is dirty or there is dirty water in the tank Clean the ceramic membrane and replace the water w...

Page 16: ...an w dokumentacji Technicznej 5 Stwierdzone uszkodzenia urz dzenia obj tego Gwarancj nale y zg osi MAXAIR Arkadiusz Dragun 32 002 Kokot w Kokot w 703 tel 513 677 545 6 Zg oszenie reklamacyjne powinno...

Page 17: ...fabr nr silnika Nr rachunku faktury Data sprzeda y KARTA GWARANCYJNA Nazwa i adres firmy Telefon kontaktowy Osoba do kontaktu Dane zg aszaj cego reklamacj Adnotacje o przebiegu napraw Data zg oszenia...

Page 18: ...Kokot w 703 32 002 Kokot w biuro eberg eu tel 48 513 677 545 www eberg eu...

Reviews: