5. Slide the screw from Position A to Position B by
moving the heater slightly. Make sure the distance
between the bottom of the heater and the floor is
no less than 20cm when the heater is installed.
2.2.CEILING INSTALLATION
The heating panel must be at least 20 cm from all objects, walls and so on. The minimum distance from
the ceiling is 4 cm as this allows an airflow which will prevent the heating panel from overheating. The
minimum distance from the bottom of the heating panel to the floor must be 185 cm. Choose a sturdy,
even ceiling made of heat-proof material for hanging the heating panel
1. Use the H-bracket to mark the holes in the ceiling
Position the H-bracket such that, when the heating
panel is installed, the minimum distances above are
guaranteed. Make sure that the hanging frame is
installed with the correct side to the top. (see diagram)
Check and make sure that there are no cables in the
ceiling before drilling at the marked points.
2. Drill holes with drill bit.