background image

Operating instructions

A2D250-AA06-71

Translation of the original operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Direction of air flow "A"

2

Cable PVC 7G 0.5 mm²

3

Max. clearance for screw 5 mm

4

Cable diameter min. 6 mm, max. 9 mm

5

Tightening torque 1.3 ± 0.2 Nm

Item no. 15626-5-9970 · ENU · Change 96928 · Approved 2018-01-10 · Page 4 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com

Summary of Contents for A2D250-AA06-71

Page 1: ...suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1...

Page 2: ...orking on the system machine wait until all parts have come to a standstill WARNING Rotating device Long hair and dangling items of clothing jewelry and the like can become entangled and be pulled int...

Page 3: ...perating instructions Improper use In particular operating the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or...

Page 4: ...rection of air flow A 2 Cable PVC 7G 0 5 mm 3 Max clearance for screw 5 mm 4 Cable diameter min 6 mm max 9 mm 5 Tightening torque 1 3 0 2 Nm Item no 15626 5 9970 ENU Change 96928 Approved 2018 01 10 P...

Page 5: ...EN 60335 1 motor does not have factory installed overheating protection With regard to cyclic speed loads note that the rotating parts of the device are designed for a maximum of one million load cyc...

Page 6: ...witch 4 2 1 Requirements Check whether the information on the nameplate matches the connection data Before connecting the device make sure the power supply matches the device voltage Only use cables d...

Page 7: ...d in a U shaped loop wherever possible If this is not possible a drip edge can be produced by fitting a cable tie directly in front of the cable gland for example Fans installed lying flat Make sure t...

Page 8: ...inal operating instructions 4 4 Connection diagram Item no 15626 5 9970 ENU Change 96928 Approved 2018 01 10 Page 8 10 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phone 49 0 7938 81 0...

Page 9: ...ibration levels and possibly resonant frequencies must be determined in the course of fan commissioning Either run through the resonant range as quickly as possible with speed control or find another...

Page 10: ...licable country specific legal regulations with regard to the disposal of products or waste occurring in the various phases of the life cycle The corresponding disposal standards are also to be heeded...

Reviews: