background image

 

 

page 2 of 8 

 

1  SAFETY REGULATIONS AND INFORMATION 

 
Read the operating manual carefully before commencing work at the 
product. Pay attention to the following warnings to avoid risk to 
persons or malfunctioning. 
This operating manual is an integral part of the product. 
In the event of resale or change of ownership the operating manual 
must accompany the product. This operating manual may be copied 
and provided as information on potential risks and their avoidance.

 

 

Hazard classification of warning notices 

 
The following risk ratings are used in this operating manual to denote 
potential risk situations and important safety instructions: 

 

 

DANGER 

This is a potentially dangerous situation 
and warns of an impending health risk 
or risk of fatal injury if this warning is 
not observed. Observe this warning. 

 

WARNING 

The dangerous situation can occur and 
can result in major or fatal injuries if the 
warning is not observed. Work with 
extreme care. 

 

CAUTION 

The dangerous situation can occur and 
can result in minor injuries or damage 
to property if the warning is not 
observed. 

 

NOTE 

A potentially dangerous situation can 
occur and results in damage to 
property if not avoided. 

 
Qualification of personnel 
 

Only skilled electricians are permitted to install the product, to carry out 
the test run and to work at the electrical unit. 
Only instructed and authorized skilled personnel are permitted to 
transport, unpack, operate and service the product. 

 
Basic safety regulations 

 
Safety risks related to the product must be reassessed after installing 
in the final device. 
The operating manual was developed in accordance with European 
market requirements and may need adapting to the market 
requirements of the country in question. 
 
When working at the product, observe the following: 
 

Ø

 Do not make any changes to the product. 

 

 

WARNING 
Impermissible high load 

 

Ø

 Stop the product immediately after 

impermissible loading (e.g. impact, 
heat, overvoltage). 

 

 

Electrical voltage and current 

 

 

DANGER 
Electrical voltage 

 
Regularly check the electrical 
equipment of the product. 

Ø

  Eliminate immediately loose 

connections and defective cables. 

 

 

CAUTION 
In the event of a fault, the product is 
energized. 
 

Product has basic insulation. 

Ø

  Do not touch the product after 

installing. 

 

Safety and protective functions 
 

 

DANGER 
Missing safety device and faulty 
protective equipment. 

 
Without protective equipment severe 
injuries can occur, e.g. by taking hold of 
the rotating equipment. 

Ø

  Operate the product with protection 

guards only.

 

 
Electromagnetic radiation

 

 
Electromagnetic compatibility (EMC) may affect the system integration 
of the product due to interaction. 
 

Ø

 Ensure the electromagnetic compatibility of the entire system. 

 
Moving parts 

 

 

DANGER 

Self-starting product 
 

If voltage is applied, the motor 
automatically restarts after a mains 
failure or when blocking has been 
eliminated. 

Ø

  Do not stand in the danger zone of 

the product. 

Ø

  Switch off the mains voltage when 

working on the product and secure 
against switching on again. 

 

 

 

 

DANGER 
Rotating impeller 

 
Contact with the impeller may result in 
injuries. Long hair, loose-fitting 
garments and jewellery can be caught 
and pulled into the product. Risk of 
injury.

 

Ø

  Before starting the product, ensure 

that it is securely fixed and that the 
guards are in place. 

Ø

  Do not wear loose-fitting garments 

or jewellery when working on 
moving parts. 

Ø

  Protect long hair by wearing a hair 

net. 

 

 
 

 

CAUTION 
High risk of fire spreading

 

 
Can cause fire to spread. 

Ø

  Never direct the airflow 

(intake/exhaust side) at a potential 
source of fire. 

 

Hot surface 

Summary of Contents for ACi 4400 HHU-511

Page 1: ...hen making enquiries about the product ebm papst St Georgen GmbH Co KG Hermann Papst Straße 1 D 78112 St Georgen Phone 49 0 7724 81 0 Fax 49 0 7724 81 1309 info2 de ebmpapst com www ebmpapst com As per 27 09 2016 Version 0 0 Article number 9203509511 Original operating manual INDEX 1 SAFETY REGULATIONS AND INFORMATION 2 2 INTENDED USE 4 3 TECHNICAL DATA 4 4 CONNECTION AND COMMISSIONING 5 5 FAULTS ...

Page 2: ...o the market requirements of the country in question When working at the product observe the following Ø Do not make any changes to the product WARNING Impermissible high load Ø Stop the product immediately after impermissible loading e g impact heat overvoltage Electrical voltage and current DANGER Electrical voltage Regularly check the electrical equipment of the product Ø Eliminate immediately ...

Page 3: ... well protected Ensure that the storage temperature is adhered to see Chapter 3 Technical Data If the product is not operated for a longer period of time we recommend running it for approx 15 minutes annually to move the motor bearings Cleaning NOTE Product damaged during cleaning Ø Do not clean the product using a water jet or pressure washer Do not put any pressure on the rotor Do not use cleani...

Page 4: ...lated protective equipment Operating the product under conditions other than those mentioned in the technical data Furthermore all fields of application not mentioned under intended use An in situ assessment must be conducted of the heating behavior appropriate and inappropriate operation the protection against contact electrical shocks impact of foreign objects or water and the usage at altitudes...

Page 5: ...ations Ø Observe the connection regulations that are valid in your country e g fusing GFCI CAUTION Electrical voltage The product is a built in component and has no switch for disconnecting power Ø Only connect the product to current circuits that can be switched off by a switch all poles disconnected When working on the product secure the system machine in which the product is installed against s...

Page 6: ...ta Only use cables that are designed for the current on the nameplate and the corresponding ambient conditions Ensure that the electrical interface data is adequately protected mechanical Find additional information in drawing or label Wire Color Operation Check connections NOTE ACmaxx and ACi fans are built in products and must not be earthed Connect product Check the product for visible damage a...

Page 7: ... inspection min 1 2 yearly Fixation of wires Visual inspection min 1 2 yearly Insulation of wires Visual inspection min 1 2 yearly Check impeller for wear sediments corrosion Visual inspection min 1 2 yearly 6 COMPLIANCE The product bears the CE mark The CE mark is affixed to adequately sized nameplates Within the meaning of the EMC Guideline 2014 30 EU this document is intended as Mounting instru...

Page 8: ...page 8 of 8 ...

Reviews: