2.

 

PROPER USE 

The device is exclusively designed as a built-in device for 

moving water according to its technical data. 

Any other or secondary use is deemed improper and constitutes 

a misuse of the device. 

Customer equipment must be capable of withstanding the 
mechanical and thermal streses that can arise from this product.  

This applies for the entire service life of the equipment in which 

this product is installed. 

Proper use also includes: 

 

Using the device in accordance with the permitted 

ambient temperature, see chapter 3.5 Transport and 

storage conditions and chapter 3.2 Nominal data. 

 

Operating the device with all protective features in 
place. 

 

Minding the operating instructions. 

Improper use 

Using the device in the following ways is particularly prohibited 

and may cause hazards:

 

 

Operating the device with an imbalance, e.g. caused 

by dirt deposits or icing. 

 

Moving water that contains abrasive particles. 

 

Moving highly corrosive water, e.g. salt water  

 

Operating the device close to flammable materials or 
components. 

 

Operating the device in an explosive atmosphere. 

 

Using the device as a safety component or for taking 

on safety-related functions. 

 

Operation with completely or partially disassembled 
or modified protective features. 

 

Opening the terminal box during operation. 

 

In addition, all application options that are not listed 
under proper use. 

 

Summary of Contents for ALPHA

Page 1: ...device If the device is sold or transferred the operating instructions must accompany it These operating instructions may be duplicated and forwarded for information about potential dangers and their...

Page 2: ...Rotating device Body parts that come into contact with the rotor can be injured Secure the device against accidental contact Before working on the system machine wait until all parts have come to a s...

Page 3: ...this product is installed Proper use also includes Using the device in accordance with the permitted ambient temperature see chapter 3 5 Transport and storage conditions and chapter 3 2 Nominal data...

Page 4: ...3 9360 6464 ABN 33 115 927 556 NSW Phone 61 02 9827 6400 NSW Fax 61 02 9827 6464 NZ Phone 64 09 525 0245 NZ Fax 64 09 525 0246 sales ebmpapst com au www ebmpapst com au EBM ALPHA 3 TECHNICAL DATA 3 1...

Page 5: ...type of protection IP 44 depending on installation and position Junction box type of protection Must be stored in a dry environment Insulation class B Humidity class F1 2 Mounting position Any Conden...

Page 6: ...agree with the connection data and the data of the operating capacitor Before connecting the device ensure that the supply voltage matches the operating voltage of the device Only use cables designed...

Page 7: ...h for the supply line When disconnecting be sure to disconnect the earth wire connection last 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Return t...

Page 8: ...r high pressure washer Do not use any cleaners containing acids bases or solvents Do not use any pointed or sharp edged objects to clean 5 2 Safety test What has to be tested How to test Frequency Whi...

Reviews: