Check the
protective
casing against
accidental
contact for
damage and to
ensure that it is
intact

Visual inspection At least every

6 months

Repair or
replacement of
the device

Check the
device for
damage to
blades and
housing

Visual inspection At least every

6 months

Replacement
of the device

Mounting the
connection lines

Visual inspection At least every

6 months

Fasten

Mounting of
protective
earth connection

Visual inspection At least every

6 months

Fasten

Check the
insulation of
the wires for
damage

Visual inspection At least every

6 months

Replace wires

Condensate
discharge
holes for
clogging, as
necessary

Visual inspection At least every

6 months

Open bore holes

Check the ball
bearings to
ensure they
are quiet, can
move easily
and are free of
play

Manual check
by turning the
rotor in shut-off
state

At least every
6 months

Replace
device in case
of noise,
difficulty of
movement or
clearance of
the bearings

Item no.: 51198-5-9970 · Revision: 73287 · Print-out: 2012-04-11 · Y. Uhlmann (VM-TDO) · Page 12 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com

Summary of Contents for G1G170-AB05-81

Page 1: ...d to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards stemming from the device must be re ev...

Page 2: ...Escaping gas may also cause explosions Never open the blower WARNING Rotating device Long hair loose items of clothing and jewellery could become entangled and pulled into the device You could be inju...

Page 3: ...ating instructions Using the device in accordance with the permitted ambient temperature see chapter 3 5 Transport and storage conditions and chapter Only using the device in stationary systems Instal...

Page 4: ...addition all application options that are not listed under proper use Item no 51198 5 9970 Revision 73287 Print out 2012 04 11 Y Uhlmann VM TDO Page 4 12 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 7...

Page 5: ...nnector No 926 884 1 2 1 L 2 2 N 2 3 PE 3 5 pole strip mating connector not included in delivery Molex No 39 01 4050 female connector Molex No 39 00 0059 3 1 10V output max 10mA 3 2 Speed monitoring 3...

Page 6: ...l bearing Technical features Output 10 VDC max 10 mA Tach output Motor current limit Control input 0 10 VDC PWM Over temperature protected motor Leakage current 3 5 mA Electrical leads With plug Motor...

Page 7: ...ectrical voltage The device is a built in component and features no electrically isolating switch Connect the device only to circuits that can be switched off using an all pole disconnecting switch Wh...

Page 8: ...sing an all pole disconnecting switch When working on the device you must switch off the system machine in which the device is installed and secure it from being switched on again Check the PIN assign...

Page 9: ...power supply for ext devices e g potentiometer SELV ST2 2 DUE Speed monitoring 3 pulses per revolution SELV ST2 3 0 10V Control input 0 10 V impedance 100k SELV ST2 4 PWM Control input PWM 1 6 kHz SE...

Page 10: ...supply Start the device by changing the input signal 4 7 Switching off the device Switching off the device during operation Switch on the device via the control input Do not switch the motor e g in c...

Page 11: ...ean the device if imbalance is still evident after cleaning replace the device If you have attached any weight clips during cleaning make sure to remove them afterwards Motor does not turn Mechanical...

Page 12: ...ion At least every 6 months Fasten Check the insulation of the wires for damage Visual inspection At least every 6 months Replace wires Condensate discharge holes for clogging as necessary Visual insp...