background image

Operating instructions

G1G170-AB05-81

Translation of the original operating instructions

CAUTION
In the event of failure, there is electric voltage at the
rotor and impeller

The rotor and impeller are base insulated.
→ Do not touch the rotor and impeller once they are installed.

CAUTION
If control voltage is applied or a speed setpoint is stored,
the motor automatically restarts, e.g. after a power failure.

Danger of injury
→ Keep out of the danger zone of the device.
→ When working on the device, switch off the mains

supply voltage and secure the latter from being switched on
again.

→ Wait until the device stops.
→ After working on the device, remove any used tools or

other objects from the device.

1.5 Safety and protective functions

DANGER
Missing safety device and non-functioning safety device

If there is no safety device, you could be seriously injured, for
example by reaching into the running device with your hands.
→ Operate the device only with a fixed and isolating safety

protection and a fixed guard grille. The guard must withstand
the kinetic energy of a fan blade detaching at maximum
speed.

→ The device is a built-in component. You, the owner/

operator, are responsible for providing adequate protection for
the device.

→ Instantly stop the device once you detect a missing or

ineffective protective feature.

1.6 Electromagnetic radiation

Interference from electromagnetic radiation is possible, e.g. in conjunction
with open and closed-loop control devices.
If unacceptable emission intensities occur when the fan is installed,
appropriate shielding measures have to be taken by the user.

NOTE
Electrical or electromagnetic interferences after
integrating the device in installations on the customer's
side.

→ Verify that the entire setup is EMC compliant.

1.7 Mechanical movement

DANGER
Danger of injury from open blower

Gas escapes. When the blower is open, you come into contact
with rotating and electrically live parts. Escaping gas may also
cause explosions.
→ Never open the blower.

WARNING
Rotating device

Long hair, loose items of clothing and jewellery could become
entangled and pulled into the device. You could be injured.
→ Do not wear any loose clothing or jewellery while working

on rotating parts.

→ Protect long hair by wearing a cap.

WARNING
Flying parts

Missing safety devices may cause fan blades to be ejected at
high speeds, causing bodily harm.
→ Take appropriate safety measures.

The safety devices must prevent contact with rotating parts
and the printed circuit board.

1.8 Deflagration

DANGER
Gas escapes through leaky housing after deflagration

Danger of injury
→ After a deflagration, check that the housing of the gas blower

is tightly sealed.

→ Replace any gas blower with a leaky housing.

DANGER
Fire and deflagration hazard

The gas blower is not approved according to Ex protection
guidelines. Rotating parts can scrape against stationary parts.
This may cause sparks and chips. The surface temperature
may rise, resulting in a fire.
→ Check which hazards arise from installing, operating,

servicing or disposing the gas blower in conjunction with
your device.
Prevent these hazards.
Carry out all appropriate measures to this purpose.

1.9 Emission

WARNING
Depending on the installation and operating conditions,
a sound pressure level greater than 70 dB(A) may arise.

Danger of noise-induced hearing loss
→ Take appropriate technical safety measures.
→ Protect operating personnel with appropriate safety

equipment, e.g. hearing protection.

→ Also observe the requirements of local agencies.

1.10 Hot surface

CAUTION
High temperature at the electronics enclosure

Danger of burn injuries
→ Ensure that sufficient protection against accidental contact is

provided.

1.11 Transport

NOTE
Transport of blower

→ Transport the blower in its original packaging only.
→ Secure the blower so that it does not slip, e.g. by using a

clamping strap.

Item no.: 51198-5-9970 · Revision: 73287 · Print-out: 2012-04-11 · Y. Uhlmann (VM-TDO) · Page 2 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com

Summary of Contents for G1G170-AB05-81

Page 1: ...d to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards stemming from the device must be re ev...

Page 2: ...Escaping gas may also cause explosions Never open the blower WARNING Rotating device Long hair loose items of clothing and jewellery could become entangled and pulled into the device You could be inju...

Page 3: ...ating instructions Using the device in accordance with the permitted ambient temperature see chapter 3 5 Transport and storage conditions and chapter Only using the device in stationary systems Instal...

Page 4: ...addition all application options that are not listed under proper use Item no 51198 5 9970 Revision 73287 Print out 2012 04 11 Y Uhlmann VM TDO Page 4 12 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 7...

Page 5: ...nnector No 926 884 1 2 1 L 2 2 N 2 3 PE 3 5 pole strip mating connector not included in delivery Molex No 39 01 4050 female connector Molex No 39 00 0059 3 1 10V output max 10mA 3 2 Speed monitoring 3...

Page 6: ...l bearing Technical features Output 10 VDC max 10 mA Tach output Motor current limit Control input 0 10 VDC PWM Over temperature protected motor Leakage current 3 5 mA Electrical leads With plug Motor...

Page 7: ...ectrical voltage The device is a built in component and features no electrically isolating switch Connect the device only to circuits that can be switched off using an all pole disconnecting switch Wh...

Page 8: ...sing an all pole disconnecting switch When working on the device you must switch off the system machine in which the device is installed and secure it from being switched on again Check the PIN assign...

Page 9: ...power supply for ext devices e g potentiometer SELV ST2 2 DUE Speed monitoring 3 pulses per revolution SELV ST2 3 0 10V Control input 0 10 V impedance 100k SELV ST2 4 PWM Control input PWM 1 6 kHz SE...

Page 10: ...supply Start the device by changing the input signal 4 7 Switching off the device Switching off the device during operation Switch on the device via the control input Do not switch the motor e g in c...

Page 11: ...ean the device if imbalance is still evident after cleaning replace the device If you have attached any weight clips during cleaning make sure to remove them afterwards Motor does not turn Mechanical...

Page 12: ...ion At least every 6 months Fasten Check the insulation of the wires for damage Visual inspection At least every 6 months Replace wires Condensate discharge holes for clogging as necessary Visual insp...

Reviews: