You can control the blower either via the 0-10 VDC input or the
PWM input. Note: Inputs cannot be used simultaneously.

3.2 Nominal data

Motor

M1G074-CF

Phase

1~

Nominal voltage in VAC

115

Frequency in Hz

50/60

Type of data definition

fa

Speed in min

-1

5730

Power input in W

345

Current draw in A

4.0

Min. ambient
temperature in °C

- 25

Max. ambient
temperature in °C

+ 55

Min. temp. of flow
medium in °C

-25

Max. temp. of flow
medium in °C

+80

ml = max. load · me = max. efficiency · fa = running at free air

cs = customer specs · cu = customer unit

Subject to alterations

3.3 Technical description

Mass

4.4 kg

Size

170 mm

Surface of rotor

Coated in black

Material of protective
cover

Polyflam RPP 374-ND CS1 (UL 97-V0)

Material of impeller

Aluminium sheet

Housing material

Die-cast aluminium

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP 20

Insulation class

"B"

Humidity class

F0

Mounting position

Any

Cooling bore / aperture

Rotor-side

Operation mode

S1

Premix

If gas is premixed in the blower, a
special blower must be used. Contact us
for details.

Motor bearing

Ball bearing

Technical features

- Output 10 VDC, max. 10 mA
- Tach output
- Motor current limit
- Control input 0-10 VDC / PWM
- Over-temperature protected motor

Leakage current

<= 3.5 mA

Electrical leads

With plug

Motor protection

Thermal overload protector (TOP) wired
internally

Approval

UL 507; CSA C22.2 Nr.113

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.4 Mounting data

For depth of screw, see chapter 3.1 Graphic rendition of products

;

Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.5 Transport and storage conditions

;

Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+80 °C

Min. permissible
ambient motor temp.
(transp./storage)

-40 °C

3.6 Electromagnetic compatibility

EMC interference
immunity

Acc. to EN 61000-6-2

EMC interference
emission

Acc. to EN 61000-6-3 (household
environment)

Item no.: 51198-5-9970 · Revision: 73287 · Print-out: 2012-04-11 · Y. Uhlmann (VM-TDO) · Page 6 / 12

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com

Summary of Contents for G1G170-AB05-81

Page 1: ...d to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards stemming from the device must be re ev...

Page 2: ...Escaping gas may also cause explosions Never open the blower WARNING Rotating device Long hair loose items of clothing and jewellery could become entangled and pulled into the device You could be inju...

Page 3: ...ating instructions Using the device in accordance with the permitted ambient temperature see chapter 3 5 Transport and storage conditions and chapter Only using the device in stationary systems Instal...

Page 4: ...addition all application options that are not listed under proper use Item no 51198 5 9970 Revision 73287 Print out 2012 04 11 Y Uhlmann VM TDO Page 4 12 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 7...

Page 5: ...nnector No 926 884 1 2 1 L 2 2 N 2 3 PE 3 5 pole strip mating connector not included in delivery Molex No 39 01 4050 female connector Molex No 39 00 0059 3 1 10V output max 10mA 3 2 Speed monitoring 3...

Page 6: ...l bearing Technical features Output 10 VDC max 10 mA Tach output Motor current limit Control input 0 10 VDC PWM Over temperature protected motor Leakage current 3 5 mA Electrical leads With plug Motor...

Page 7: ...ectrical voltage The device is a built in component and features no electrically isolating switch Connect the device only to circuits that can be switched off using an all pole disconnecting switch Wh...

Page 8: ...sing an all pole disconnecting switch When working on the device you must switch off the system machine in which the device is installed and secure it from being switched on again Check the PIN assign...

Page 9: ...power supply for ext devices e g potentiometer SELV ST2 2 DUE Speed monitoring 3 pulses per revolution SELV ST2 3 0 10V Control input 0 10 V impedance 100k SELV ST2 4 PWM Control input PWM 1 6 kHz SE...

Page 10: ...supply Start the device by changing the input signal 4 7 Switching off the device Switching off the device during operation Switch on the device via the control input Do not switch the motor e g in c...

Page 11: ...ean the device if imbalance is still evident after cleaning replace the device If you have attached any weight clips during cleaning make sure to remove them afterwards Motor does not turn Mechanical...

Page 12: ...ion At least every 6 months Fasten Check the insulation of the wires for damage Visual inspection At least every 6 months Replace wires Condensate discharge holes for clogging as necessary Visual insp...

Reviews: