background image

Operating instructions

G2E160-AY50-91

Translation of the original operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All measures have the unit mm.

1

Connection line silicone 4G 0.5 mm², 4x lead tips crimped

Item no. 14128-5-9970 · ENG · Revision 202174 · Release 2018-12-28 · Page 4 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com

Summary of Contents for G2E160-AY50-91

Page 1: ...al staff Only authorised specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules Any...

Page 2: ...s that come into contact with the rotor and impeller can be injured Secure the device against accidental contact Before working on the system machine wait until all parts have come to a standstill WAR...

Page 3: ...evice with an imbalance e g caused by dirt deposits or icing Resonance mode operation with heavy vibrations These also include vibrations that are transmitted from the customer system to the fan Opera...

Page 4: ...duct drawing All measures have the unit mm 1 Connection line silicone 4G 0 5 mm 4x lead tips crimped Item no 14128 5 9970 ENG Revision 202174 Release 2018 12 28 Page 4 11 ebm papst Mulfingen GmbH Co K...

Page 5: ...ller Sheet steel galvanised Housing material Die cast aluminium Direction of rotation Clockwise seen on rotor Type of protection IP44 Depending on installation and position Insulation class F Humidity...

Page 6: ...sure that the cable end is connected in a dry environment Connect the device only to circuits that can be switched off using an all pole disconnecting switch 4 2 1 Prerequisites Check that the data o...

Page 7: ...irst connect the PE protective earth connection Connect the lines according to your application When doing so observe chapter 4 4 Connection screen Item no 14128 5 9970 ENG Revision 202174 Release 201...

Page 8: ...ctions 4 4 Connection screen U1 blue Z brown U2 black PE green yellow Item no 14128 5 9970 ENG Revision 202174 Release 2018 12 28 Page 8 11 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen...

Page 9: ...ALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Return the device to ebm papst for repair or replacement WARNING Terminals and connections have voltage even with a u...

Page 10: ...recommendations for ecological disposal of the product and its components 5 3 1 Country specific legal requirements NOTE Country specific legal requirements Always observe the applicable country spec...

Page 11: ...ploying the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 14128 5 9970 ENG Revision 202174 Release 2018 12 28 Page 11 11 ebm papst Mulfing...