background image

Operating instructions

G3G160-RO31-04

Translation of the original operating instructions

3. TECHNICAL DATA

3.1 Product drawing

All dimensions in mm.

1

Cable PVC AWG22
3x splice

2

Cable PVC AWG20
3x splice

3

Tapping hole prepared for self-tapping screw for fastening plastics (Remform) dia. 4 mm, screw-in depth max. 9 mm, torque is to be
determined on the basis of the screw.

4

5x sheet metal nut for thread EN ISO 1478-ST4.8 (max. screw length 20 mm plus thickness of mounting material)

5

Screw-on domes are only permissible for Flowgrid!

6

Connecting sleeve not suitable for installation with pipe clamps

Item no. 56997-5-9970 · ENU · Change 260698 · Approved 2022-07-01 · Page 4 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com

Summary of Contents for G3G160-RO31-04

Page 1: ...authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basi...

Page 2: ...easures have to be taken by the user NOTE Electrical or electromagnetic interference after installing the device in customer equipment Verify that the entire setup is EMC compliant 1 7 Mechanical move...

Page 3: ...prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration...

Page 4: ...th max 9 mm torque is to be determined on the basis of the screw 4 5x sheet metal nut for thread EN ISO 1478 ST4 8 max screw length 20 mm plus thickness of mounting material 5 Screw on domes are only...

Page 5: ...the component s intended installation and connection Conformity with standards EN 60335 1 CE UKCA Approval CCC Use the device in accordance with its degree of protection Information on surface quality...

Page 6: ...s damage can result Ensure that the device is securely positioned at its place of installation until all fastening screws have been tightened The fan must not be strained on fastening 4 2 Electrical c...

Page 7: ...he motor is at a standstill and the line voltage is switched on The values are typically in the range 50 mA At the same time the effective power in this operating state operational readiness is typica...

Page 8: ...neutral conductor see nameplate for voltage range CON12 1 PE green yellow Protective earth CON130 3 RSB brown RS485 interface for MODBUS RSB SELV CON130 2 RSA white RS485 interface for MODBUS RSA SELV...

Page 9: ...und connection last 5 INTEGRATED PROTECTIVE FEATURES The integrated protective functions cause the motor to switch off automatically in the event of the faults described in the table Fault Safety feat...

Page 10: ...ary after that period contact ebm papst Adapt the maintenance intervals to the actual level of dust exposure 6 2 Safety inspection NOTE High voltage test The integrated EMC filter has Y capacitors The...

Page 11: ...lating materials Cables and wires Electronic scrap e g circuit boards Only ferrite magnets and not rare earth magnets are used in external rotor motors from ebm papst Mulfingen GmbH Co KG Ferrite magn...