4.4 Connection diagram

Note: Change of rotation direction by reversing two phases

Δ

Delta connection

Y

Star connection

L1

black

L2

blue

L3

brown

U1

black

V1

blue

W1

brown

U2

green

V2

white

W2

yellow

TOP

2x gray

PE

green/yellow

Item no. 16627-5-9970 · ENU · Change 251972 · Approved 2022-02-16 · Page 8 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com

Summary of Contents for G4D200-BL19-03

Page 1: ...d by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installatio...

Page 2: ...Verify that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller Secure the device against...

Page 3: ...following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also i...

Page 4: ...Product drawing All dimensions in mm 1 Cable halogen free BETAtrans 3 GKW flex 9G 0 75 mm 9x splice Item no 16627 5 9970 ENU Change 251972 Approved 2022 02 16 Page 4 11 ebm papst Mulfingen GmbH Co KG...

Page 5: ...ective earth is connected by the customer This component for installation may have several local protection classes This information relates to this component s basic design The final protection class...

Page 6: ...ple devices connected in parallel Electric shock risk of injury Ensure sufficient protection against accidental contact Before working on the electrical hookup short the supply and PE connections CAUT...

Page 7: ...to a suitable tripping unit Only connect the device to circuits that can be switched off with an all pole disconnection switch When working on the device secure the system machine in which the device...

Page 8: ...phases Delta connection Y Star connection L1 black L2 blue L3 brown U1 black V1 blue W1 brown U2 green V2 white W2 yellow TOP 2x gray PE green yellow Item no 16627 5 9970 ENU Change 251972 Approved 2...

Page 9: ...ALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING Live terminals and connections even with device switch...

Page 10: ...on At least every 6 months Fasten Fastening the protective earth terminal Visual inspection At least every 6 months Fasten Insulation of cables for damage Visual inspection At least every 6 months Rep...

Page 11: ...aterials and are therefore to be treated in the same manner The materials concerned are as follows Miscellaneous insulators used in the terminal box Power cables Cables for internal wiring Electrolyti...

Reviews: