background image

Operating instructions

M2E068-CF10-65

Translation of the original operating instructions

→ Wait five minutes after disconnecting the voltage at all poles

before opening the device.

CAUTION
In the event of a fault, the rotor and the impeller will be
energized

The rotor and the impeller have basic insulation.
→ Do not touch the rotor and impeller once installed.

CAUTION
The motor restarts automatically when operating voltage
is applied, e.g. after a power failure.

Risk of injury
→ Keep out of the motor's danger zone.
→ When working on the motor, switch off the line voltage

and ensure that it cannot be switched back on.

→ Wait until the motor comes to a stop.

1.5 Mechanical movement

WARNING
Rotating device

Long hair and dangling items of clothing, jewelry and the like
can become entangled and be pulled into the device. Injuries
can result.
→ Do not wear any loose-fitting or dangling clothing or jewelry

while working on rotating parts.#Protect long hair with a cap.

WARNING
Ejected parts

If the motor is operated with attached fan blades, missing
protective devices may allow balancing weights or broken fan
blades to be ejected and cause injuries.
→ Take appropriate safety measures such as installing guard

grilles.

→ Keep out of the exhaust zone.

1.6 Hot surface

CAUTION
High temperature on motor housing

Risk of burns
→ Ensure sufficient protection against accidental contact.

1.7 Transport

CAUTION
Transporting the motor

Crushing hazard
→ Wear safety shoes and cut-resistant safety gloves.
→ Transport the motor in its original packaging only.
→ Secure the device so it cannot slip, e.g. by using a

lashing strip.

1.8 Storage

;

Store the device, partially or fully assembled, in a dry and
weatherproof manner in the original packaging in a clean environment.

;

Protect the device against environmental effects and dirt until final
installation.

;

We recommend storing the device for no longer than one year in
order to guarantee trouble-free operation and the longest possible
service life.

;

Even devices explicitly intended for outdoor use are to be stored as
described prior to commissioning.

;

Maintain the storage temperature, see
Chapter 3.5 Transport and storage conditions.

2. INTENDED USE

The device is designed exclusively for use as a drive motor.
Any other usage above and beyond this does not conform with the
intended purpose and constitutes misuse of the device.
Customer equipment must be capable of withstanding the mechanical
and thermal stresses that can arise from this product. This applies for the
entire service life of the equipment in which this product is installed.

Intended use also includes

Using the device within the permitted ambient temperature range; see
Chapter 3.5 Transport and storage conditions and
Chapter 3.2 Nominal data.

Operating the device with all protective devices.

Following the operating instructions.

Improper use

In particular, operating the device in the following ways is prohibited and
could be hazardous:

Conveying air that contains abrasive particles.

Conveying highly corrosive air, e.g. salt spray. Exception: devices
designed for salt spray and correspondingly protected.

Conveying air with high dust content, e.g. suctioning off sawdust.

Operating the device close to flammable materials or components.

Operating the device in an explosive atmosphere.

Using the device as a safety component or to perform safety-related
functions.

Operation with completely or partially disassembled or manipulated
protective devices.

In addition, all applications not listed among the intended uses.

Item no. 11403-5-9970 · ENU · Change 89188 · Approved 2016-04-18 · Page 2 / 8

Summary of Contents for M2E068-CF

Page 1: ...ded can lead to property damage 1 2 Staff qualifications 1 1 2 Staff qualifications The device may only be transported unpacked installed operated maintained and otherwise used by suitably qualified t...

Page 2: ...ner in the original packaging in a clean environment Protect the device against environmental effects and dirt until final installation We recommend storing the device for no longer than one year in o...

Page 3: ...lation of the original operating instructions 3 TECHNICAL DATA 3 1 Product drawing All dimensions in mm 1 Cable PVC 4G 0 5 mm 4x crimped splices 2 Max clearance for screw 5 mm Item no 11403 5 9970 ENU...

Page 4: ...ards EN 60335 1 CE With regard to cyclic speed loads note that the rotating parts of the device are designed for a maximum of one million load cycles If you have special questions consult ebm papst fo...

Page 5: ...section is at least AWG 26 0 13 mm Ground conductor contact resistance according to EN 60335 Compliance with the impedance specifications according to EN 60335 for the protective earth connection cir...

Page 6: ...instructions M2E068 CF10 65 Translation of the original operating instructions 4 4 Connection diagram U1 blue Z brown U2 black PE green yellow Item no 11403 5 9970 ENU Change 89188 Approved 2016 04 18...

Page 7: ...alfunction fault Possible cause Possible remedy Rotor not running smoothly Imbalance in rotating parts Clean the device replace it if imbalance persists after cleaning Motor not turning Mechanical blo...

Page 8: ...sal The products are mostly made of steel copper aluminum and plastic Metallic materials are generally considered to be fully recyclable Separate the components for recycling into the following catego...