background image

Operating instructions

M2E068-CF10-65

Translation of the original operating instructions

3.2 Nominal data

Motor

M2E068-CF

Phase

1~

Nominal voltage / VAC

230

Frequency / Hz

50

Method of obtaining
data

me

Valid for approval/
standard

CE

Speed (rpm) / min

-1

2600

Power consumption / W

85

Power output / W

47

Current draw / A

0.38

Rated torque / Ncm

17.4

Mean starting torque
/ Ncm

11.5

Capacitor / µF

2

Capacitor voltage / VDB

450

Min. ambient
temperature / °C

-25

Max. ambient
temperature / °C

45

Starting current / A

0.74

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Technical description

Fan size

68 mm

Rotor surface

Painted black

Direction of rotation

Clockwise, viewed toward rotor

Degree of protection

IP44; installation- and position-dependent
as per EN 60034-5

Insulation class

"B"

Moisture (F) /
Environmental (H)
protection class

H0+

Installation position

Shaft horizontal or rotor on top; rotor on
bottom on request

Condensation
drainage holes

On stator side

Mode

S1

Motor bearing

Ball bearing

Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)

< 0.75 mA

Motor protection

Thermal overload protector (TOP)
internally connected

with cable

Variable

Protection class

I (with customer connection of protective
earth)

Conformity with
standards

EN 60335-1; CE

With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.

3.4 Mounting data

For screw clearance, see Chapter 3.1 Product drawing

;

Secure the screws against unintentional loosening (e.g. use self-
locking screws).

Strength class of
screws

8.8

Any further mounting data required can be taken from the product drawing.

3.5 Transport and storage conditions

;

Use the device in accordance with its degree of protection.

Max. permitted
ambient temp. for
motor (transport/
storage)

+ 80 °C

Min. permitted
ambient temp. for
motor (transport/
storage)

- 40 °C

4. CONNECTION AND STARTUP

4.1 Mechanical connection

WARNING
Hot motor housing

Risk of fire
→ Ensure that no combustible or flammable materials are

located close to the motor.

CAUTION
Cutting and crushing hazard when removing motor from
packaging

→ Carefully remove the device from its packaging. Strictly

avoid shocks.

→ Wear safety shoes and cut-resistant safety gloves.

;

Check the device for transport damage. Damaged devices are not to
be installed.

;

Install the undamaged device in accordance with your application.

CAUTION
Possible damage to the device

If the device slips during installation, serious damage can result.
→ Ensure that the device is securely positioned at its place of

installation until all fastening screws have been tightened.

Item no. 11403-5-9970 · ENU · Change 89188 · Approved 2016-04-18 · Page 4 / 8

Summary of Contents for M2E068-CF

Page 1: ...ded can lead to property damage 1 2 Staff qualifications 1 1 2 Staff qualifications The device may only be transported unpacked installed operated maintained and otherwise used by suitably qualified t...

Page 2: ...ner in the original packaging in a clean environment Protect the device against environmental effects and dirt until final installation We recommend storing the device for no longer than one year in o...

Page 3: ...lation of the original operating instructions 3 TECHNICAL DATA 3 1 Product drawing All dimensions in mm 1 Cable PVC 4G 0 5 mm 4x crimped splices 2 Max clearance for screw 5 mm Item no 11403 5 9970 ENU...

Page 4: ...ards EN 60335 1 CE With regard to cyclic speed loads note that the rotating parts of the device are designed for a maximum of one million load cycles If you have special questions consult ebm papst fo...

Page 5: ...section is at least AWG 26 0 13 mm Ground conductor contact resistance according to EN 60335 Compliance with the impedance specifications according to EN 60335 for the protective earth connection cir...

Page 6: ...instructions M2E068 CF10 65 Translation of the original operating instructions 4 4 Connection diagram U1 blue Z brown U2 black PE green yellow Item no 11403 5 9970 ENU Change 89188 Approved 2016 04 18...

Page 7: ...alfunction fault Possible cause Possible remedy Rotor not running smoothly Imbalance in rotating parts Clean the device replace it if imbalance persists after cleaning Motor not turning Mechanical blo...

Page 8: ...sal The products are mostly made of steel copper aluminum and plastic Metallic materials are generally considered to be fully recyclable Separate the components for recycling into the following catego...

Reviews: