background image

Operating instructions

P2E076-AC06-01

Translation of the original operating instructions

3.2 Nominal data

Motor

M2E068-CF

Phase

1~

1~

Nominal voltage / VAC

230

230

Frequency / Hz

50

60

Type of data definition

ml

ml

Valid for approval /
standard

CE

CE

Speed / min

-1

2600

2750

Power input / W

90

125

Current draw / A

0.40

0.56

Motor capacitor / µF

2

2

Capacitor voltage / VDB

400

400

Capacitor standard

-

Max. ambient
temperature / °C

45

45

Pump capacity / m

3

/h

1.0

1.1

Max. Pumping head / m

6.8

8.4

ml = max. load · me = max. efficiency · fc = free conveying

cs = customer specs · cu = customer unit

Subject to alterations

3.3 Technical features

Mass

2.0 kg

Size

76 mm

Surface of rotor

Coated in black

Material of impeller

ABS plastic, 15 % fibreglass-reinforced

Material of agitator
propeller

PE

Material of pump
housing

ABS plastic, 15 % fibreglass-reinforced

Material of cross-
member

Stainless steel

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP 44

Insulation class

"B"

Humidity class

F2-2

Mounting position

Vertical

Condensate discharge
holes

None

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

< 0.75 mA

Motor protection

Thermal overload protector (TOP) wired
internally

Cable exit

Variable

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 60335-1; CE

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.4 Mounting data

For depth of screw, see chapter 3.1 Product drawing

;

Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.5 Transport and storage conditions

;

Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

Item no. 10615-5-9970 · Revision 68158 · Release 2010-11-29 · Page 5 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com

Summary of Contents for P2E076-AC06-01

Page 1: ...he electrical system Only trained and authorised specialist personnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules...

Page 2: ...be ejected resulting in bodily harm Take appropriate safety measures 1 7 Emission WARNING Depending on the installation and operating conditions a sound pressure level greater than 70 dB A may arise...

Page 3: ...5 Transport and storage conditions and chapter 3 2 Nominal data Minding the operating instructions Improper use Using the device in the following ways is particularly prohibited and may cause hazards...

Page 4: ...Product drawing All measures have the unit mm 1 Connection line silicone 4G 4x brass lead tips crimped Item no 10615 5 9970 Revision 68158 Release 2010 11 29 Page 4 9 ebm papst Mulfingen GmbH Co KG B...

Page 5: ...e discharge holes None Operation mode S1 Motor bearing Ball bearing Touch current acc IEC 60990 measuring network Fig 4 TN system 0 75 mA Motor protection Thermal overload protector TOP wired internal...

Page 6: ...e Make sure that the cable end is connected in a dry environment Connect the device only to circuits that can be switched off using an all pole disconnecting switch 4 2 1 Prerequisites Check whether t...

Page 7: ...tructions 4 4 Connection screen U1 blue Z brown U2 black PE green yellow Item no 10615 5 9970 Revision 68158 Release 2010 11 29 Page 7 9 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Ph...

Page 8: ...and secure the latter from being switched on again Wait until the pump stops If the device remains out of use for some time e g when in storage we recommend switching the device on for at least two ho...

Page 9: ...sual inspection At least every 6 months Replace device Mounting the connection lines Visual inspection At least every 6 months Fasten Mounting of protective earth connection Visual inspection At least...