Line

No.

Signal

Colour

Function / assignment

4

L

black

Power supply 230 VAC, 50-60 Hz, see type plate for voltage range

3

N

blue

Neutral conductor

1

PE

green/
yellow

Protective earth

8

0-10 V PWM

yellow

Control input 0 - 10 V or PWM, electrically isolated

9

Tach

white

Tach output: open collector, 1 pulse per revolution, electrically isolated

11

10V / max 1.1
mA

red

Voltage output 10 V / max. 1.1 mA, electrically isolated

12

GND

blue

GND - Connection for control interface

Item no. 51069-5-9970 · Revision 72864 · Release 2011-02-18 · Page 7 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com

Summary of Contents for R3G190-AF50-01

Page 1: ...sonnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards stemming from the d...

Page 2: ...ire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Body parts that come into contact with the rotor and impeller can be injured Secure the device against accidental contact Befo...

Page 3: ...the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that contains abrasive particles Moving highl...

Page 4: ...blue 1 3 PE green yellow 2 1 Tach output white 2 2 GND blue 2 3 10V red 2 4 0 10V yellow 3 Depth of screw min 8 mm max 10 mm 4 Pilot hole prepared for self tapping screw M4 depth of screw max 6 mm 5...

Page 5: ...chnical features Motor current limit Soft start Control input 0 10 VDC PWM Over temperature protected electronics motor Touch current acc IEC 60990 measuring network Fig 4 TN system 3 5 mA Motor prote...

Page 6: ...ssible Maintain a distance to the power supply line when routing the control lines of the device Ensure a sufficiently large clearance Recommendation clearance 10 cm separate cable routing NOTE Water...

Page 7: ...8 0 10 V PWM yellow Control input 0 10 V or PWM electrically isolated 9 Tach white Tach output open collector 1 pulse per revolution electrically isolated 11 10V max 1 1 mA red Voltage output 10 V ma...

Page 8: ...on Switch on the device via the control input Do not switch the motor e g in cyclic operation on and off via power supply Switching off the device for maintenance work Switch on the device via the con...

Page 9: ...tector responded Allow motor to cool off locate and rectify cause of error if necessary cancel restart lock out Overtemperature of electronics motor Insufficient cooling Improve cooling Let the device...

Page 10: ...ge Visual inspection At least every 6 months Clean or replace impeller Check the ball bearings to ensure they are quiet can move easily and are free of play Manual check by turning the rotor in shut o...

Page 11: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information ebm papst R3G190 AF50 01...

Reviews: