Operating instructions
R3G310-RQ10-C6
Translation of the original operating instructions
3.2 Nominal data
Motor
M3G084-GF
Phase
3~
Nominal voltage / VAC
400
Nominal voltage
range / VAC
380 .. 480
Frequency / Hz
50/60
Method of obtaining
data
ml
Speed (rpm) / min
-1
2650
Power consumption / W
740
Current draw / A
1.4
Min. ambient
temperature / °C
-25
Max. ambient
temperature / °C
60
ml = Max. load · me = Max. efficiency · fa = Free air
cs = Customer specification · ce = Customer equipment
Subject to change
3.3 Data according to ErP Directive
Actual
Req. 2015
01 Overall efficiency η
es
/ %
66.2
50
02 Measurement category
A
03 Efficiency category
Static
04 Efficiency grade N
78.2
62
05 Variable speed drive
Yes
06 Year of manufacture
The year of manufacture is specified on the
product's rating label.
07 Manufacturer
ebm-papst Mulfingen GmbH & Co. KG
Amtsgericht (court of registration) Stuttgart
· HRA 590344
D-74673 Mulfingen
08 Type
R3G310-RQ10-C6
09 Power consumption P
ed
/ kW
0.72
09 Air flow q
v
/ m³/h
2110
09 Pressure increase total p
sf
/
Pa
747
10 Speed (rpm) n / min
-1
2655
11 Specific ratio
*
1.01
12 Recycling/disposal
Information on recycling and disposal is
provided in the operating instructions.
13 Maintenance
Information on installation, operation and
maintenance is provided in the operating
instructions.
14 Additional components
Components used to calculate the energy
efficiency that are not apparent from the
measurement category are detailed in the
CE declaration.
*
Specific ratio = 1 + p
fs
/ 100 000 Pa
Data obtained at optimum efficiency level. The ErP data is determined using a motor-impeller
combination in a standardized measurement setup.
3.4 Technical description
Weight
6.5 kg
Fan size
310 mm
Rotor surface
Painted black
Electronics housing
material
Die-cast aluminum
Impeller material
PP plastic
Number of blades
6
Direction of rotation
Clockwise, viewed toward rotor
Degree of protection
IP54
Insulation class
"B"
Moisture (F) /
Environmental (H)
protection class
F3-1
Installation position
Shaft horizontal or rotor on top; rotor on
bottom on request
Condensation
drainage holes
None
Mode
S1
Motor bearing
Ball bearing
Technical features
- Output 10 VDC, max. 10 mA
- Output 20 VDC, max. 50 mA
- Output for slave 0-10 V
- Input for sensor 0-10 V or 4-20 mA
- External 24 V input (parameter setting)
- Alarm relay
- Integrated PID controller
- Motor current limitation
- PFC, passive
- RS-485 MODBUS-RTU
- Soft start
- Control input 0-10 VDC / PWM
- Control interface with SELV potential
safely disconnected from supply
- Thermal overload protection for
electronics/motor
- Line undervoltage / phase failure
detection
Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)
<= 3.5 mA
Electrical hookup
Via terminal box
Motor protection
Thermal overload protector (TOP)
internally connected
Protection class
I (if protective earth is connected by
customer to the housing's connection point)
Conformity with
standards
EN 61800-5-1; CE
Approval
UL 1004-7 + 60730; C22.2 No.77 +
CAN/CSA-E60730-1
With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.
Item no. 52000-5-9970 · ENU · Change 89187 · Approved 2016-04-15 · Page 5 / 12