background image

Operating instructions

S4E300-AS72-30

Translation of the original operating instructions

4.4 Connection screen

U1

blue

Z

brown

U2

black

PE

green/yellow

Item no. 11024-5-9970 · Revision 79663 · Release 2013-04-23 · Page 7 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com

Summary of Contents for S4E300-AS72-30

Page 1: ...he electrical system Only trained and authorised specialist personnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules...

Page 2: ...could become entangled and pulled into the device You could be injured Do not wear any loose clothing or jewellery while working on rotating parts Protect long hair by wearing a cap 1 7 Emission WARNI...

Page 3: ...the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that contains abrasive particles Moving highl...

Page 4: ...g All measures have the unit mm 1 Direction of air flow V 2 Connection line PVC 4 x 0 5 mm 4 x brass lead tips crimped Item no 11024 5 9970 Revision 79663 Release 2013 04 23 Page 4 9 ebm papst Mulfing...

Page 5: ...class F1 2 Mounting position Any Condensate discharge holes None Operation mode S1 Motor bearing Ball bearing Touch current acc IEC 60990 measuring network Fig 4 TN system 0 75 mA Motor protection The...

Page 6: ...connection data and the data of the operating capacitor Before connecting the device ensure that the supply voltage matches the operating voltage of the device Only use cables designed for current acc...

Page 7: ...tructions 4 4 Connection screen U1 blue Z brown U2 black PE green yellow Item no 11024 5 9970 Revision 79663 Release 2013 04 23 Page 7 9 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Ph...

Page 8: ...off Electric shock risk of injury Discharge the capacitors before working on the device CAUTION The motor restarts automatically when operating voltage is applied e g after a power failure Danger of i...

Page 9: ...k the protective casing against accidental contact for damage and to ensure that it is intact Visual inspection At least every 6 months Repair or replacement of the device Check the device for damage...

Reviews: