3.2 Nominal data

Motor

M4E110-GF

Phase

1~

1~

Nominal voltage / VAC

230

230

Frequency / Hz

50

60

Type of data definition

ml

ml

Valid for approval /
standard

CE

CE

Speed / min

-1

1330

1490

Power input / W

710

920

Current draw / A

3.1

4.05

Motor capacitor / µF

14

14

Capacitor voltage / VDB

450

450

Max. back pressure / Pa

160

100

Min. ambient temperature
/ °C

-40

Max. ambient
temperature
/ °C

70

60

Starting current / A

6.2

Maximum safe operating
speed / min

-1

1785

1785

ml = Max. load · me = Max. efficiency · fa = Running at free air

cs = Customer specs · cu = Customer unit

Subject to alterations

3.3 Data according to ErP directive

Installation category

A

Efficiency category

Static

Variable speed drive

No

Specific ratio

*

1.00

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Actual

Request
2013

Request
2015

Overall efficiency η

es

/ %

32.5

28.5

32.5

Efficiency grade N

40

36

40

Power input P

e

/ kW

0.65

Air flow q

v

/ m³/h

5605

Pressure increase total p

sf

/ Pa

133

Speed n / min

-1

1350

Data definition with optimum efficiency.

The ErP data is determined using a motor-impeller combination in a standardised

measurement configuration.

3.4 Technical features

Mass

13.5 kg

Size

500 mm

Surface of rotor

Cast in aluminium

Material of terminal box

PC / ABS plastic

Material of blades

Aluminium sheet

Material of guard grille

Steel, coated in black plastic (RAL9005)

Number of blades

5

Blade angle

-5°

Direction of air flow

"V"

Direction of rotation

Counter-clockwise, seen on rotor

Type of protection

IP 54

Insulation class

"F"

Humidity class

F3-1

Mounting position

Shaft horizontal or rotor on bottom; rotor
on top on request

Condensate discharge
holes

Rotor-side

Operation mode

S1

Motor bearing

Ball bearing

Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)

<= 3.5 mA

Electrical leads

Via terminal box, integrated capacitor
connected via terminal box

Motor protection

Thermal overload protector (TOP)
brought out

Cable exit

Axial

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 61800-5-1; CE

Approval

CSA C22.2 Nr.100; EAC; UL 1004-1;
VDE

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.5 Mounting data

;

Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.6 Transport and storage conditions

;

Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+80 °C

Min. permissible
ambient motor temp.
(transp./storage)

-40 °C

Item no. 10420-5-9970 · Revision 82542 · Release 2014-05-08 · Page 5 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com

Summary of Contents for S4E500-AE03-01

Page 1: ...Only authorised specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety h...

Page 2: ...ng hair loose items of clothing and jewellery could become entangled and pulled into the device You could be injured Do not wear any loose clothing or jewellery while working on rotating parts Protect...

Page 3: ...imbalance e g caused by dirt deposits or icing Operation in medical equipment with a life sustaining or lifesaving function Operation with external vibrations Moving solids content in flow medium Pai...

Page 4: ...e the unit mm 1 Direction of air flow V 2 Tightening torque 1 5 0 2 Nm 3 Cable diameter min 6 mm max 12 mm tightening torque 2 0 0 3 Nm Item no 10420 5 9970 Revision 82542 Release 2014 05 08 Page 4 11...

Page 5: ...astic RAL9005 Number of blades 5 Blade angle 5 Direction of air flow V Direction of rotation Counter clockwise seen on rotor Type of protection IP 54 Insulation class F Humidity class F3 1 Mounting po...

Page 6: ...l pole disconnecting switch 4 2 1 Prerequisites Check whether the data on the type plate agree with the connection data and the data of the operating capacitor Before connecting the device ensure that...

Page 7: ...rap Fig 2 Fan installed lying flat cable routed as a water trap Fans installed in upright position When routing the cable ensure that the screwed cable glands are arranged at the bottom The cables mus...

Page 8: ...ns 4 4 Connection screen L U1 blue Z brown N U2 black PE green yellow TOP grey Item no 10420 5 9970 Revision 82542 Release 2014 05 08 Page 8 11 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfi...

Page 9: ...that all screws and screwed cable glands are properly tightened 4 7 Switch on device The device may only be switched on if it has been installed properly and in accordance with its intended use includ...

Page 10: ...tage faulty Check mains supply voltage restore power supply Faulty connection De energise correct connection see connection diagram Thermal overload protector responded Allow motor to cool off locate...

Page 11: ...d seams for crack formation Visual inspection At least every 6 months Replace device Item no 10420 5 9970 Revision 82542 Release 2014 05 08 Page 11 11 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 7467...