Operating instructions
W2G110-AG43-01
Translation of the original operating instructions
3.2 Nominal data
Motor
M2G045-BA
Nominal voltage / VDC
24
Nominal voltage
range / VDC
16 .. 28
Type of data definition
fa
State
prelim.
Speed / min
-1
4200
Power input / W
15
Min. ambient
temperature / °C
- 25
Max. ambient
temperature / °C
72
ml = max. load · me = max. efficiency · fa = running at free air
cs = customer specs · cu = customer unit
Subject to alterations
3.3 Technical features
Mass
0.5 kg
Size
110 mm
Surface of rotor
Coated in black
Material of blades
Sheet steel, coated in black
Material of wall ring
Die-cast aluminium, coated in black
Number of blades
5
Direction of rotation
"V"
Type of protection
IP 22
Insulation class
"B"
Mounting position
Any
Operation mode
S1
Motor bearing
Ball bearing
Motor protection
Reverse polarity and locked-rotor
protection
Product conforming
to standard
EN 60950-1
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.4 Mounting data
For depth of screw, see chapter 3.1 Product drawing
;
Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.5 Transport and storage conditions
;
Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+ 80 °C
Min. permissible
ambient motor temp.
(transp./storage)
- 25 °C
Item no. 51380-5-9970 · Revision 74353 · Release 2012-08-22 · Page 5 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com