background image

Operating instructions

W2G110-AG43-01

Translation of the original operating instructions

3.2 Nominal data

Motor

M2G045-BA

Nominal voltage / VDC

24

Nominal voltage
range / VDC

16 .. 28

Type of data definition

fa

State

prelim.

Speed / min

-1

4200

Power input / W

15

Min. ambient
temperature / °C

- 25

Max. ambient
temperature / °C

72

ml = max. load · me = max. efficiency · fa = running at free air

cs = customer specs · cu = customer unit

Subject to alterations

3.3 Technical features

Mass

0.5 kg

Size

110 mm

Surface of rotor

Coated in black

Material of blades

Sheet steel, coated in black

Material of wall ring

Die-cast aluminium, coated in black

Number of blades

5

Direction of rotation

"V"

Type of protection

IP 22

Insulation class

"B"

Mounting position

Any

Operation mode

S1

Motor bearing

Ball bearing

Motor protection

Reverse polarity and locked-rotor
protection

Product conforming
to standard

EN 60950-1

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.4 Mounting data

For depth of screw, see chapter 3.1 Product drawing

;

Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.5 Transport and storage conditions

;

Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 25 °C

Item no. 51380-5-9970 · Revision 74353 · Release 2012-08-22 · Page 5 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com

Summary of Contents for W2G110-AG43-01

Page 1: ...Only trained and authorised specialist personnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules 1 1 3 Basic safety ru...

Page 2: ...parts have come to a standstill WARNING Rotating device Long hair loose items of clothing and jewellery could become entangled and pulled into the device You could be injured Do not wear any loose cl...

Page 3: ...Using the device in the following ways is particularly prohibited and may cause hazards Operating the device with an imbalance e g caused by dirt deposits or icing Moving air that contains abrasive pa...

Page 4: ...ct drawing All measures have the unit mm 1 Direction of air flow V 2 Connection line 2 x AWG22 300 V red blue Item no 51380 5 9970 Revision 74353 Release 2012 08 22 Page 4 9 ebm papst Mulfingen GmbH C...

Page 5: ...r protection Reverse polarity and locked rotor protection Product conforming to standard EN 60950 1 For cyclic speed loads note that the rotating parts of the device are designed for maximum one milli...

Page 6: ...ted in a dry environment Operate the device with a safely isolated power pack 4 2 1 Prerequisites Check whether the data on the type plate agree with the connection data Before connecting the device e...

Page 7: ...ion assignment 1 1 UN 24V red Power supply 24 V voltage range refer to rating plate residual ripple 3 5 1 2 GND blue Reference mass Item no 51380 5 9970 Revision 74353 Release 2012 08 22 Page 7 9 ebm...

Page 8: ...AUTION If control voltage is applied or a speed setpoint is stored the motor automatically restarts e g after a power failure Danger of injury Keep out of the danger zone of the device When working on...

Page 9: ...tal contact for damage and to ensure that it is intact Visual inspection At least every 6 months Repair or replacement of the device Check the device for damage to blades and housing Visual inspection...

Reviews: