background image

Operating instructions

W3G300-ME46-01

Translation of the original operating instructions

3.2 Nominal data

Motor

M3G084-BF

Nominal voltage / VDC

26

Nominal voltage
range / VDC

16 .. 32

Method of obtaining
data

fa

Speed (rpm) / min

-1

3000

Power consumption / W

175

Current draw / A

6.7

Min. ambient
temperature / °C

-40

Max. ambient
temperature / °C

85

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Technical description

Weight

2 kg

Size

300 mm

Motor size

84

Blade material

PA plastic

Fan housing material

PP plastic

Number of blades

7

Airflow direction

V

Direction of rotation

Clockwise, viewed toward rotor

Degree of protection

Motor IP24 KM, electronics IP6K9K
(mating connector installed)

Insulation class

"B"

Moisture (F) /
Environmental (H)
protection class

H4

Ambient temperature
note

Occasional start-up at temperatures
between -40°C and -25°C is permitted.
For continuous operation at ambient
temperatures below -25°C (such as
refrigeration applications), use must be
made of a fan design with special low-
temperature bearings.

Installation position

Any

Mode

S1

Motor bearing

Ball bearing; (sealed)

Life expectancy

40,000 h (depending on load profile and
ambient conditions)

Technical features

- Locked-rotor detection
- Error output (high-side switch)
- Power limiter
- Load dump protection
- Motor current limitation
- Soft start
- Control input 0-10 VDC / PWM
- Temperature derating
- Thermal overload protection for
electronics
- Reverse polarity protection

Electrical hookup

Plug; Standby current less than 500 µA

Protection class
assignment

0; Built-in component with basic
insulation, protection class is based on
the intended installation.
This component for installation may
have several local protection classes.
This information relates to this
component’s basic design.
The final protection class is based on
the component’s intended installation and
connection.

Approval

EAC; E1

Comment

Type approval number - 069401

;

Use the device in accordance with its degree of protection.

Information on surface quality

The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may change during the production period.
This has no effect on strength, dimensional stability and dimensional
accuracy.
The color pigments in the paints used perceptibly react to UV light over
the course of time. The product is to be protected against UV radiation to
prevent the formation of patches and fading. Changes in color are not a
reason for complaint and are not covered by the warranty. UV radiation
in the frequency range and the intensity of natural solar radiation has no
effect on the technical properties of the products.

3.4 Mounting data

Further mounting data can be taken from the product drawing or Chapter
4.1 Mechanical connection as required.

Strength class of
screws

8.8

For screw clearance, see Chapter 3.1 Product drawing

;

Secure the screws against unintentional loosening (e.g. use self-
locking screws).

3.5 Transport and storage conditions

Max. permitted
ambient temp. for
motor (transport/
storage)

+85 °C

Min. permitted
ambient temp. for
motor (transport/
storage)

-40 °C

Item no. 57879-5-9970 · ENU · Change 262216 · Approved 2022-09-19 · Page 5 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com

Summary of Contents for W3G300-ME46-01

Page 1: ...packed installed operated maintained and otherwise used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test...

Page 2: ...opriate shielding measures have to be taken by the user NOTE Electrical or electromagnetic interference after installing the device in customer equipment Verify that the entire setup is EMC compliant...

Page 3: ...hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration transmitted to the fan...

Page 4: ...2 4 GND Accessory part Cable 460 mm with mating connector part no 02040 4 1021 not included in scope of delivery 4 pole mating connector TE 1 1718628 1 2x plug contact TE 1 968857 1 2x plug contact TE...

Page 5: ...lt in component with basic insulation protection class is based on the intended installation This component for installation may have several local protection classes This information relates to this...

Page 6: ...s have been tightened The fan must not be strained on fastening 4 2 Electrical connection CAUTION Voltage The fan is a built in component and has no disconnecting switch Only connect the fan to circui...

Page 7: ...t Ri 27 k 0 10 V typ 0 5 V Standby 1 5 V n min 9 5 V n max or PWM 12 V Ub 1 kHz 10 kHz typ 1 standby 10 n min 95 n max 13 2 1 DIAG Diagnostic output Open Collector Isorce max 10 mA Rsource 2 k Rsink 1...

Page 8: ...not switch the motor e g in cyclic operation on and off via power supply Disconnect the device from the power supply 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs...

Page 9: ...every 6 months Replace device Abnormal bearing noise acoustic At least every 6 months Replace device 5 3 Disposal For ebm papst environmental protection and resource preservation are top priority cor...

Page 10: ...r internal wiring Electrolytic capacitors Dispose of electronic components employing the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 578...

Reviews: