Operating instructions
W3G300-XG06-01
Translation of the original operating instructions
3.2 Nominal data
Motor
M3G074-DF
Phase
1~
Nominal voltage / VAC
230
Nominal voltage
range / VAC
200 .. 277
Frequency / Hz
50/60
Method of obtaining
data
ml
Speed (rpm) / min
-1
2400
Power consumption / W
320
Current draw / A
1.4
Max. back pressure / Pa
310
Min. ambient
temperature / °C
-25
Max. ambient
temperature / °C
60
ml = Max. load · me = Max. efficiency · fa = Free air
cs = Customer specification · ce = Customer equipment
Subject to change
3.3 Data according to Commission Regulation (EU) 327/
2011
Actual
Req. 2015
01 Overall efficiency η
es
/ %
48.3
30.5
02 Measurement category
A
03 Efficiency category
Static
04 Efficiency grade N
57.8
40
05 Variable speed drive
Yes
06 Year of manufacture
The year of manufacture is specified on the
product's rating label.
07 Manufacturer
ebm-papst Mulfingen GmbH & Co. KG
Amtsgericht (court of registration) Stuttgart ·
HRA 590344
D-74673 Mulfingen
08 Type
W3G300-XG06-01
09 Power consumption P
ed
/ kW
0.31
09 Air flow q
v
/ m³/h
2310
09 Pressure increase total p
fs
/
Pa
214
10 Speed (rpm) n / min
-1
2400
11 Specific ratio
*
1.00
12 Recycling/disposal
Information on recycling and disposal is
provided in the operating instructions.
13 Maintenance
Information on installation, operation and
maintenance is provided in the operating
instructions.
14 Additional components
Components used to calculate the energy
efficiency that are not apparent from the
measurement category are detailed in the
CE declaration.
*
Specific ratio = 1 + p
fs
/ 100 000 Pa
Data obtained at optimum efficiency level. The efficiency values displayed for achieving
conformity with the Ecodesign Regulation EU 327/2011 has been reached with defined air
duct components (e.g. inlet rings). The dimensions must be requested from ebm-papst. If
other air conduction geometries are used on the installation side, the ebm-papst evaluation
loses its validity/the conformity must be confirmed again. The product does not fall within
the scope of Regulation (EU) 2019/1781 due to the exception specified in Article 2 (2a)
(motors completely integrated into a product).
3.4 Technical description
Size
300 mm
Motor size
74
Rotor surface
Thick-film passivated
Terminal box material
PP plastic
Impeller material
PP plastic
Inlet ring material
Sheet steel, galvanized and coated with
black plastic (RAL 9005)
Number of blades
5
Airflow direction
V
Direction of rotation
Clockwise, viewed toward rotor
Degree of protection
IP54
Insulation class
"B"
Moisture (F) /
Environmental (H)
protection class
H1
Installation position
Shaft horizontal or rotor on bottom; rotor
on top on request
Cooling hole/opening
On rotor side
Mode
S1
Motor bearing
Ball bearing
Technical features
- Output 10 VDC, max. 10 mA
- Operation and alarm display
- Alarm relay
- Integrated PID controller
- Power limiter
- Motor current limitation
- PFC, active
- RS-485 MODBUS-RTU
- Soft start
- Control input 0-10 VDC / PWM
- Control interface with SELV potential
safely disconnected from the mains
- Thermal overload protection for
electronics/motor
- Line undervoltage / phase failure
detection
Touch current
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)
<= 3.5 mA
Electrical hookup
Terminal box
Motor protection
Thermal overload protector (TOP)
internally connected
with cable
Variable
Protection class
I (with customer connection of protective
earth)
Conformity with
standards
EN 60034-1; EN 60204-1; EN 60335-1;
CE
Approval
CSA C22.2 No. 77 + CAN/CSA-
E60730-1; EAC; UL 1004-7 + 60730-1
;
Use the device in accordance with its degree of protection.
Item no. 58074-5-9970 · ENU · Change 264288 · Approved 2022-07-20 · Page 5 / 12
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com