39
Configuration
© 2013 EBS
9.2.3.1.4.4 Number of connection attempts
In this field you determine how often device will try to make connection to backup
server. If connections fail, Active Track after execution of some connection will back
to procedure of connection to primary server.
9.2.3.1.4.5 Disconnect after time limit
If you mark this choice field the device will disconnect from back up server after
passage of set time. Further operation depends on defined parameter Order of
connection (See clause
). If this option is active the device
reconnects to the primary server. If this option is not active the device firstly
completes connection to backup server procedure and if this fails, the device will try
to connect to the primary server.
9.2.3.1.5 Access
9.2.3.1.5.1 Service code
It provides security against unauthorized access. It is being used during programming
of device and during remote controlling (in TCP/IP or SMS mode). Factory setting is
1111. During the first starting of device (programming) it shall be changed. Code
may consist of up to seven alpha numerical characters.
9.2.3.1.5.2 PIN of SIM card
As a device operates via GSM network, SIM card is indispensable and it may be
received from phone operator. Before the first use PIN code of SIM card shall be
programmed for operation in given transmitter. PIN code is indispensable for
automatic system launching. In case of card without PIN code, it is possible to enter
any value e.g. 0000.
If you enter wrong PIN number after inserting card and switching on transmitter, the
system will not launch and you may be able to use card after entering PUK card only
(with use of any GSM mobile phone).
Factory setting of PIN in Active Track transmitter is 1111.
9.2.3.2
Transmission
For the purpose of maximum security of transmission, data is encrypted with AES key.
This option may be used for GPRS and SMS transmission. You may use your own
code (256 bytes – signs 0-9 and A-F) or use default settings.
38