CPX230NWB ALARM CONTROL UNIT – USER MANUAL
29 / 42
EN
2.
Added users will be shown (diodes from A to D - groups to which the numbers from 1
to 8 are assigned). The currently shown group will be indicated by blinking of the
corresponding diode (A-D). A continuously lit number within a group means that the
given user already exists. Other groups where users are assigned will be continuously
lit. An unlit group means that there are no users assigned there. Switch between
groups using the
button.
3.
Select a user number in the group you have selected (group A, B, C or D, numbers
from 1 to 8), different than one that has already been added. The selected number will
start blinking, press
to confirm.
4.
Partition numbers to which the new user can have access to are indicated. Pressing 1
or 2 turns the diode of the corresponding partition on or off. Once access is configured,
to confirm. All diodes should be off now.
5.
Enter the code of the newly added user (from 4 to 7 digits, depending on the defined
length) and confirm with
.
6.
Re-enter the code of the newly added user and press
to complete adding, or
to exit without saving changes.
7.
If the user has been added correctly, you will hear a triple confirmation tone, otherwise
you will hear a continuous signal.
9.7.
ARMING ONLY USER (CAN’T DISARM THE SYSTEM)
This function disables the ability of selected users to disarm the system. After enabling this
option, users will be able to arm the control panel only. You have to enter:
<administrator code>
Users whose rights to disarm have been removed will be displayed (diodes from A to D –
groups to which the numbers from 1 to 8 are assigned). The currently shown group will be
indicated by blinking of the corresponding diode (A, B, C or D). A continuously lit number
(1–8) within a group means that a user without the right to disarm already exists. Other
groups with users of this type will be continuously lit. An unlit group means that there are
no users without the right to disarm. Pressing button 1–8 on the keypad activates (diode
goes on) or disables (diode goes off) option for the existing user. For a non-existent user,
pressing the button will not switch on the diode. Switch between groups using the
button.
Note: The function can be enabled/disabled for existing users in the system.
9.8.
DELETING USERS
The function deletes user codes. Codes can only be deleted by the administrator. A
correctly entered function will be confirmed with a triple tone. Default administrator code:
1111.