CPX230NWB ALARM CONTROL PANEL – INSTALLER MANUAL
10 / 144
EN
3.
INSTALLATION AND WIRING
3.1.
SEQUENCE OF INSTALLATION
1.
Develop installation diagram accounting for the location of control panel, keypad,
detectors and other system components.
2.
Install the control panel in hardly accessible place with uninterrupted power supply
ensured.
3.
Install the keypad in a location convenient for a user and connect it with the control
panel. For description of keypad installation, please refer to chapter 3.6.3 Keypad
installation.
NOTE: Maximum length of cables connecting the control panel with the
keypad, at the core diameter 0.5mm
2
cannot exceed 200m.
4.
Install detectors and door and window reed relays. Connect the installed elements with
control panel. For sample configuration of zones, please refer to chapter 3.4
Configuration of wired input zones.
5.
Install and connect signaling devices with the control panel. For sample signaling
devices connection diagrams, please refer to chapter 3.5 Sample connection of signaling
device.
6.
Complete the remaining cable connections.
7.
Connect the battery to the screw terminals BAT +, BAT- and external power 16-20VAC
to screw terminals AC, AC.
8.
Program the functions of the control panel. Programming procedure was described in
the chapters below.
NOTE: If you use more than one keyboard in the system, be sure to
address each assignment of the keyboard (see chapter 3.6.4.).
9.
Verify the operation of the system and all its components.