CPX230NWB ALARM CONTROL PANEL – INSTALLER MANUAL
81 / 144
EN
6.3.4.
Outputs
6.3.4.1.
Outputs 1 / 2 / 3
Types of outputs:
Unused
– Output is inactive.
Alarm
– Output is activated when alarm is detected.
Armed status
– Output is activated when any of the assigned partitions is armed in
any mode (stay, sleep, fully armed).
Power supply fault
– Output is activated when power supply fault is detected.
Communication loss
– Output is activated when information transmission to
server is not possible.
GSM jamming indicator
– Output is activated when jamming GSM.
Chirp
– The output is activated when arming (1 chirp) or disarming (2 chirps). The
minimum duration of the chirp signal possible to set from the configurator is 40ms.
In the case of set time for exit chirp is generated after arming, similarly in the case
of the time for entry chirp is generated after disarming.
Alarm & chirp
– The output is activated when alarm is detected or when
arming/disarming.