PX200N_Manual_en-1.11i7
Page 7 / 58
2.
FUNCTIONAL AND TECHNICAL PARAMETERS
8
Inputs: (NO/NC)
1 (sabotage input)
Outputs:
Sabotage (
OUT1
) - 1 (
OC
)
Additional (NC,NO,C) - 1 (relay)*
Phone input compatible with
DTMF standard
YES
Digital interface:
RS232 (RxD, TxD, RTS, CTS lines)
Operation modes:
GPRS transmission only
SMS transmission only
GPRS and SMS transmission
Messages:
Sending of text messages for defined mobile
phones
Configuration:
Remote - via GPRS link
Remote - SMS
Remote - CSD
Locally - from PC with the use of software and
RS-232 link
Security:
SMS/GPRS transmission – AES encoding
Sabotage (OUT1) –
OC type
Additional (NC, NO, C)
- relay
Output current:
Max. 1A
Max. 100mA
Voltage supply :
18VAC (16-20VAC)
Current consumption
average/max.:
80mA / 300mA @18VAC**
Dimension:
141mm x 73mm x 35mm
Charge current:
Max. 220mA
Charge voltage:
13,8V
Used batteries:
Acid-leaded 12V
Battery failure voltage
threshold:
11VDC
+12V Output current
Max. 200mA
Used GSM/GPRS modems:
Siemens MC55i, Siemens MC55, Siemens
MC56, Wavecom Q55, Simcom SIM300C,
Simcom SIM340C
*
Device can be equipped in additional OC type output (OUT2)
**
Measured with full charged battery