background image

Chengdu Ebyte Electronic Technology Co.,Ltd

E30-400M30S

4463

User

Manual

Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.

11

1.0

2021-08-09

Content updated

Linson

About us

Technical support: support@cdebyte.com
Documents and RF Setting download link: www.ebyte.com
Thank you for using Ebyte products! Please contact us with any questions or suggestions: info@cdebyte.com
-------------------------------------------------------------------------------------------------
Phone: +86 028-61399028
Web: www.ebyte.com
Address: B5 Mould Park, 199# Xiqu Ave, High-tech District, Sichuan, China

Summary of Contents for 4463

Page 1: ...E30 400M30S 4463 SI4463 400MHz 1W SPI Wireless Module ...

Page 2: ... APPLICATION 4 2 SPECIFICATION AND PARAMETER 5 2 1 LIMIT PARAMETER 5 2 2 OPERATING PARAMETER 5 3 SIZE AND PIN DEFINITION 6 4 RECOMMENDED CIRCUIT DIAGRAM 7 5 HARDWARE DESIGN 7 6 FAQ 8 6 1 COMMUNICATION RANGE IS TOO SHORT 8 6 2 MODULE IS EASY TO DAMAGE 8 6 3 BER BIT ERROR RATE IS HIGH 9 7 PRODUCTION GUIDANCE 9 8 E30 SERIES 9 9 ANTENNA RECOMMENDATION 9 10 PACKAGE METHOD FOR BULK ORDER 10 REVISION HIS...

Page 3: ...production use modification or disclosure to third parties of this document or any part thereof without the express permission of EBYTE is strictly prohibited The information contained herein is provided as is and EBYTE assumes no liability for the use of the information No warranty either express or implied is given including but not limited with respect to the accuracy correctness reliability an...

Page 4: ...ption as well It has been widely used in various industries and has the characteristics of stable performance long transmission distance and strong ability of penetration and diffraction etc 1 2 Features The measured communication distance is up to 5 6km Maximum transmission power 1W 425 525MHz ultra wide frequency band Air date rate 1k 25kbps With 3 3 5 5V power supply over 5 V guarantees the bes...

Page 5: ...l Max Operating voltage V 3 3 5 0 5 5 5 V ensures output power Communication level V 3 3 For 5V TTL it may be at risk of burning down Operating temperature 40 85 Industrial grade Operating frequency MHz 425 525 Power Consump tion TX current mA 550 650 700 Instant power consumption RX current mA 22 Sleep current μA 2 Max TX power dBm 29 30 30 5 Receiving sensitivity dBm 120 121 122 Air data rate is...

Page 6: ...O port see SI4463manual for details 7 IO_3 Output Configurable universal GPIO port see SI4463manual for details 8 IO_0 Output Configurable universal GPIO port see SI4463manual for details 9 VCC Power supply 3 3 5 5V 5V is recommended It is also recommended to add external ceramic filter capacitor 10 VCC Power supply 3 3 5 5V 5V is recommended It is also recommended to add external ceramic filter c...

Page 7: ...ded Please pay attention to the correct connection of the positive and negative poles of the power supply reverse connection may cause permanent damage to the module Please check the power supply to ensure that between the recommended supply voltage if exceeding the maximum the module will be permanently damaged Please check the stability of the power supply Voltage can not fluctuate greatly and f...

Page 8: ...s TTL protocol at 400MHz The mounting structure of antenna has a great influence on the performance of the module It is necessary to ensure that the antenna is exposed preferably vertically upward When the module is mounted inside the case use a good antenna extension cable to extend the antenna to the outside When the antenna is installed inside a metal case it will cause the transmission distanc...

Page 9: ... welded according to the specification the module may be permanently damaged 8 E30 series Model No IC Frequency Hz Tx power dBm Distance km Air data rate bps Package Size mm Antenna E30 170T20D SI4463 170M 20 2 0 1k 25k DIP 21 36 SMA K E30 170T27D SI4463 170M 27 5 0 1k 25k DIP 24 43 SMA K E30 433T20S3 SI4438 433M 20 2 5 1k 25k SMD 16 26 IPEX STAMP E30 433T20S SI4438 433M 20 2 5 1k 25k SMD 17 30 IP...

Page 10: ... Version Date Description Issued by Model No Type Frequeny Hz Interface Gain dBi Hight mm Cable mm Function feature TX433 JZLW 15 Rubber 433M IPEX 1 3 0 165 150 Rubber antenna for cabinet omnidirectional TX433 FPC 5711 FPC 433M IPEX 1 2 5 57 68 Cost effective TX433 PCB 3207 PCB 433M IPEX 1 2 0 32 90 PCB antenna TX433 FPC 4516 FPC 433M IPEX 1 2 0 45 120 Cost effective TX433 FPC 3208 FPC 433M IPEX 1...

Page 11: ...021 08 09 Content updated Linson About us Technical support support cdebyte com Documents and RF Setting download link www ebyte com Thank you for using Ebyte products Please contact us with any questions or suggestions info cdebyte com Phone 86 028 61399028 Web www ebyte com Address B5 Mould Park 199 Xiqu Ave High tech District Sichuan China ...