Chengdu Ebyte Electronic Technology Co.,Ltd.
Copyright ©2012–2021
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
30
module).
Set the
command
AT+IREBOOT=<mode>
OK
The
description
of the
parameter
< mode >: restart mode;
0: Restart the communication module immediately.
1: Wait for the wireless frames currently being sent within the communication
module to complete before restarting.
Returns the
value
description
example
AT+IREBOOT=1
OK
Precautions
After the communication module receives the instruction, it replies to OK and
restarts the communication module. No subsequent AT instructions are received
until the restart is
complete.
Command
character
The
command
type
The command format
response
CLPM
(Enable
low
power
consumption).
Test
command
AT+CLPM=?
+CLPM:"Mode"
OK
Set the
command
AT+CLPM=<mode>
OK
The
description
of the
parameter
< mode >: Low power mode
1: The device enters low power consumption
Returns the
value
description
example
AT+CLPM=1
OK
Precautions
After entering low power consumption, the serial instruction can be sent again to
wake up;
Because the UART starting bytes may transmit incorrectly when transmitting
above 40kbps, AT-CLPM-0 may be recognized as an error and
returned to
the
"CME ERROR"and itis recommended to use "0000000D00D0A" (16-in) for
wake-up
Command
character
The
command
type
The command format
response