background image

Chengdu Ebyte Electronic Technology Co.,Ltd.

E78-868LN22S(6601)User manual

Copyright ©2012–2021

Chengdu Ebyte Electronic Technology Co.,Ltd.

5

28

SPI_SCK

Input/output

SPI SCK test point is internally connected and cannot

be used as an external SPI

For the pin definition, software driver and communication protocol of the module, please refer to ASR

official

ASR6601 Datasheet

3.3 Recommended connection diagram

Summary of Contents for ASR6601

Page 1: ...E78 868LN22S 6601 ASR6601 Wireless module...

Page 2: ...NG PARAMETERS 1 2 3 PARAMETER DESCRIPTION 2 3 MECHANICAL DIMENSIONS AND PIN DEFINITION 3 3 1 E78 868LN22S 6601 DIMENSION DRAWING 3 3 2 PIN DEFINITION 4 3 3 RECOMMENDED CONNECTION DIAGRAM 5 4 TERMS AND...

Page 3: ...oduction use modification or disclosure to third parties of this document or any part thereof without the express permission of EBYTE is strictly prohibited The information contained herein is provide...

Page 4: ...des external communication interface using standard UART With easy configuration of AT instructions users can access the standard LoraWan network 2000 is the perfect choice for current IoT application...

Page 5: ...munication Interface SPI 0 10Mbps Dimensions 20 14mm Antenna interface IPEX stamp hole the equivalent impedance is about 50 2 3 Parameter description When designing the power supply circuit for the mo...

Page 6: ...certain error a single LRC component has an error of 0 1 but hesitate to use multiple LRC components in the entire RF loop there will be a situation of error accumulation resulting in a difference be...

Page 7: ...impedance 12 GND Ground wire connected to the power reference ground 13 GND Ground wire connected to the power reference ground 14 GND Ground wire connected to the power reference ground 15 GND Groun...

Page 8: ...byte Electronic Technology Co Ltd 5 28 SPI_SCK Input output SPI SCK test point is internally connected and cannot be used as an external SPI For the pin definition software driver and communication pr...

Page 9: ...the application to perform the server s downlink transmission within a short time after the terminal s uplink transmission Downlink transmission by the server at any other time has to wait for the nex...

Page 10: ...anual Copyright 2012 2021 Chengdu Ebyte Electronic Technology Co Ltd 7 speed is low when the distance is far away and the speed is high when the distance is close This greatly improves the effective b...

Page 11: ...nsists of nodes gateways Lora NetWork Server and application servers The nodes are generally designed by LoRa chip the gateway is designed by SX1301 provided by semtech Lora NetWork Server now has ope...

Page 12: ...ogy Co Ltd 9 6 Access Demo This demo kit is E78 868LN22S 6601 as a node E890 as a gateway to access the free TTN TheThingsNetwork test server for communication testin The corresponding settings of the...

Page 13: ...al Copyright 2012 2021 Chengdu Ebyte Electronic Technology Co Ltd 10 The TTN node data record is as follows Node serial port Note Please refer to LORAWAN Node Gateway TTN Server Configuration Tutorial...

Page 14: ...a1 para2 para3 CR LF Command prefix CMD Controls the indicator op The instruction operator It can be Represents the current value of the query parameter Indicates the execution of the instruction Repr...

Page 15: ...read frequency point mask FreqBandMask CULDLMODE Set read Ul Dl mode same or different frequencies CWORKMODE Set read mode normal mode CCLASS Set read class type Class A C CBL Read the power level CST...

Page 16: ...r Manufacturer s logo Returns the value description example AT CGMI CGMI Ebyte OK Precaution s Command character The command type The command format response CGMM Read the module ID Query command AT C...

Page 17: ...ification Query command AT CGSN CGSN sn OK The description of the parameter sn Product serial number identification Returns the value description example AT CGSN CGSN 0539349E00032523 OK Precaution s...

Page 18: ...escription example AT CJOINMODE 0 OK Precaution s Different mode nodes are accessed in different ways abP please use this instruction setting before sending data Command character The command type The...

Page 19: ...or reads appEUIto return Y1Y2 Y8 16 feed format value 8 bytes Command character The command type The command format response CAPPKEY Set up AppKey Test command AT CAPPKEY CAPPKEY AppKey length is 32...

Page 20: ...ue 4 bytes Command character The command type The command format response CAPPSKEY Set up AppSKey Test command AT CAPPSKEY CAPPSKEY AppSKey length is 32 Query command AT CAPPSKEY value CAPPSKEY value...

Page 21: ...QBANDMASK mask OK Query command AT CFREQBANDMASK CFREQBANDMASK mask OK Set the command AT CFREQBANDMASK m ask OK The description of the parameter mask Frequency point masks that the network may work w...

Page 22: ...AT CWORKMODE CWORKMODE mode OK Query command AT CWORKMODE CWORKMODE mode OK Set the command AT CWORKMODE mode OK The description of the parameter mode 2 Normal working mode Returns the value descripti...

Page 23: ...fully 04 JOIN success only in the first JOIN process 05 JOIN failure only in the first JOIN process 06 Network May Be Abnormal Link Check Results 07 Send data successfully no downstream 08 Send data s...

Page 24: ...MAIN period with values ranging from 7 to 255 in s Factory default 8 ParaTag4 represents the maximum number of JOIN attempts and paraTag4 values range from 1 to 255 Returns the value description exam...

Page 25: ...sful TX_LEN 1Byte the length of the data sent OK SENT TX_CNT indicates that the data was sent successfully TX_CNT 1Byte number of data sent ERR SEND ERR_NUM indicates that the data send request failed...

Page 26: ...Length Payload OK The description of the parameter Return value Length 0 for empty packets Payload 16 feed string data OK No exceptions to receive packets Returns the value description example AT DRX...

Page 27: ...eturns the value description example AT CAPPPORT 10 OK Precautions You need to set it up before you can send the data Command character The command type The command format response CDATARATE Set the c...

Page 28: ...number 1A2 is 1 RSSI returns 8 channels in a band Returns the value description example AT CRSSI 1 CRSSI 0 157 1 157 2 157 3 157 4 157 5 157 6 157 7 157 OK Precautions Command character The command t...

Page 29: ...a 1 Cycle reporting data reportInterval This parameter is only available when periodic reporting data The time interval between periodic reporting of data in s For different DR the minimum allowed per...

Page 30: ...ontrol 0 for Link Check Not Enable Link Check 1 Perform Link Check2 once the module automatically carries the linkcheck commandin each upstream packet Return OK and set successfully If X1 is 1 after a...

Page 31: ...escription of the parameter RX1DRoffest RX2DataRate RX2Frequency Returns the value description example AT CRXP 1 1 868000000 OK Precautions You need to set it up before you can send the data Do not se...

Page 32: ...he value description example The command saves the configuration parameters to EERPOM FLASH After executing the AT RESET command the module initializes and runs the network using the new MAC configura...

Page 33: ...le No subsequent AT instructions are received until the restart is complete Command character The command type The command format response CLPM Enable low power consumption Test command AT CLPM CLPM M...

Page 34: ...echo Query command AT ECHO ECHO Mode OK Set the command AT ECHO mode OK The description of the parameter mode instruction echo 0 Directive to turn off echo 1 Directive Open Echo Returns the value des...

Page 35: ...itself is of poor quality 8 2 Module is easy to be damaged Check the power supply to ensure that the module is permanently damaged between recommended values if the maximum value is exceeded Check th...

Page 36: ...vised description Maintainer 1 0 2021 9 15 The initial version Linson About us Technical support support cdebyte com Documents and RF Setting download link www ebyte com Thank you for using Ebyte prod...

Reviews: