hengdu Ebyte Electronic Technology Co.,Ltd.
Copyright ©2012–2020
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
7
CE can be connected to high level for a long time, but the module must first be set to POWER DOWN power-down
mode when writing the register. It is recommended that CE be controlled by the single-chip pin;
The CE pin is connected to the LNA enable pin. When CE=1, the LNA is turned on, and when CE=0, the LNA is
turned off. This operation is a transceiver mode of nRF24L01;
If the user needs to answer automatically, the CE pin must maintain a high level during the transmission process,
instead of the high-level time mentioned in the n manual greater than 10us. The correct operation is:
CE=1 triggers the transmission. After knowing that the transmission is completed, it will set CE=0, instead of CE=0
after 10us. The reason is: after L01+ transmission, it will immediately switch to the receiving mode. If CE= 0, the
LNA has been turned off, which is not conducive to receiving sensitivity.
4.3 Power binning
5. Basic application
5.1 Basic circuit
No.
nRF24L01P setting power (dBm)
Module output power (dBm)
1
0dBm
27dBm
2
-6dBm
25dBm
3
-12dBm
22dBm
4
-18dBm
14dBm