4
1.2.3. Turn-off current
Model
Min
Typ
Max
Unit
Remarks
E01-ML01D
0.5
1.0
2.0
µA
● The turn-off current means the current consumed by CPU, RAM,
Clock and some registers which remain operating. SoC is at very low
power consumption status;
● The turn-off current is always lower than the current consumed
when the power supply source of the whole module is at no-load
status.
E01-ML01DP4
0.5
1.0
2.0
µA
E01-ML01DP5
0.5
1.0
2.0
µA
E01-2G4M27D
450
455
460
µA
E01-ML01IPX
0.5
1.0
2.0
µA
E01-ML01S
0.5
1.0
2.0
µA
E01-ML01SP2
0.5
1.0
2.0
µA
E01-ML01SP4
0.5
1.0
2.0
µA
1.2.4. Voltage supply
Model
Min
Typ
Max
Unit
Remarks
E01-ML01D
2.0
3.3
3.6
V DC
●If the module stays at maximum voltage for a long time, it may be
damaged;
● The power supply pin has certain surge-resistance ability, but the
potential pulse is higher than the maximum power supply voltage;
●The power supply is not advisable to be below 3.0V, or the RF
parameters will be influenced at different degree.
● For max 30dBm, voltage is no less than 4.75V,or RF parameters
will be affected to different extend.
E01-ML01DP4
2.0
3.3
3.6
V DC
E01-ML01DP5
2.0
3.3
3.6
V DC
E01-2G4M27D
2.5
3.3
5.5
V DC
E01-ML01IPX
2.0
3.3
3.6
V DC
E01-ML01S
2.0
3.3
3.6
V DC
E01-ML01SP2
2.0
3.3
3.6
V DC
E01-ML01SP4
2.0
3.3
3.6
V DC
1.2.5. Communication level
Model
Min
Typ
Max
Unit
Remarks
E01-ML01D
2.0
3.3
3.6
V DC
● If the module stays at maximum communication level for a long
time, it may be damaged;
●The module is compatible with some 5.0V MCU; Because there’s too
much model, pls refer to the real testing or consult our sales;
● There are various ways to switch communication level, but it will
affect the whole power consumption to a large extend.
E01-ML01DP4
2.0
3.3
3.6
V DC
E01-ML01DP5
2.0
3.3
3.6
V DC
E01-2G4M27D
2.0
3.3
3.6
V DC
E01-ML01IPX
2.0
3.3
3.6
V DC
E01-ML01S
2.0
3.3
3.6
V DC
E01-ML01SP2
2.0
3.3
3.6
V DC
E01-ML01SP4
2.0
3.3
3.6
V DC