Chengdu Ebyte Electronic Technology Co., Ltd.
E104-BT06 User Manual
Copyright ©2012–2018
,
Chengdu Ebyte Electronic Technology Co., Ltd
E.g.
AT+BAUD=2. Set the baud rate to 115200
HEX: 41,54,2B,42,41,55,44,3D,31,30
6.4.5 AT+PARI serial port check bit
Instruction
React
Inquire
AT+PARI?
+OK=[para]
Setting
AT+PARI=[para]
+OK
:
Done
+ERR=[NUM]
:
Error
Parameter
para(ASCII)
Description
0
No inspection (default)
1
Odd parity
2
Even parity
Description
Restart to take effect, save when power off
E.g.
AT+PARI=0
6.4.6 AT+DATABIT Serial data bit
Instruction
React
Inquire
AT+DATABIT?
+OK=[para]
Setting
AT+PARI=[para]
+OK
:
Done
+ERR=[NUM]
:
Error
Parameter
para(ASCII)
Description
0
5 data bits
1
6 data bits
2
7 data bits
3
7 data bits
Description
Restart to take effect, save when power off
E.g.
AT+PARI=0
Remark
Restart to take effect, save when power off
Maximum string length 32bytes
6.4.7 AT+ADV broadcast enable