Note: The actual reference value of transmit power.
6.5.13 Serial port baud rate
Read command format:
Command format
Command example
Send: FE 01 0C FF
Return: FB 0C baud
Send:
FE 01 0C FF
Return: FB 0C 09
Configuration instruction format:
Command format
Command example
Send: FD 01 0C baud FF
Return: FA 0C
Send: FD 01 0C 09 FF
Return: FA 0C
Baud rate parameter baud comparison table:
Note: To change the baud rate configuration of serial communication, you need to restart the device for the changed baud
rate to take effect
6.5.14 Sleep time
Read command format:
Command format
Command example
Send: FE 01 0D FF
Return: FB 0D sleep_time
Send: FE 01 0D FF
Return:
FB 0D 0A
Configuration instruction format:
Command format
Command example
Send: FD 01 0D sleep_time FF
Return: FA 0D
Send: FD 01 0D 0A FF
Return: FA 0D
When the node is a dormant terminal, the functions are as follows:
sleep_time: (1
~
60) The sleep wake-up period means 1
~
60 units (seconds)
(61
~
255) Sleep wake-up cycle representation 60+(sleep_time-60)*10 unit (seconds)
06
3
Buad
Baud rate
Buad
Baud rate
01
4800
08
76800
02
9600
09
115200
(
default
)
03
14400
0A
128000
04
19200
0B
230400
05
38400
0C
256000
06
50000
0D
460800
07
57600