Network address: 0-65535
Frequency channel: 0-83
Network ID: 0-255
Key: 0-65535
When users configure the repeater mode using the host computer, special attention must be paid. Since the
parameters are in decimal mode in the host computer, the module address and network ID need to be converted into
hexadecimal.
For example, if the network ID input by the transmitting end A is 02, and the network ID input by the receiving end
B is 10, when the repeater end R sets the module address, the hexadecimal value 0X020A is converted into the
decimal value 522 as the repeater end R. Module address.
That is, the module address value of the repeater terminal R is 522 at this time.
10. Hardware design
It is recommended to use a DC stabilized power supply. The power supply ripple factor is as small as possible, and
the module needs to be reliably grounded.
;
Please pay attention to the correct connection of the positive and negative poles of the power supply. Reverse
connection may cause permanent damage to the module
;
Please check the power supply to ensure it is within the recommended voltage otherwise when it exceeds the
maximum value the module will be permanently damaged
;
Please check the stability of the power supply, the voltage can not be fluctuated frequently
;
When designing the power supply circuit for the module, it is often recommended to reserve more than 30% of the
margin, so the whole machine is beneficial for long-term stable operation.
;
The module should be as far away as possible from the power supply, transformers, high-frequency wiring and other
parts with large electromagnetic interference.
;
High-frequency digital routing, high-frequency analog routing, and power routing must be avoided under the
module. If it is necessary to pass through the module, assume that the module is soldered to the Top Layer, and the
copper is spread on the Top Layer of the module contact part(well grounded), it must be close to the digital part of
the module and routed in the Bottom Layer
;
Assuming the module is soldered or placed over the Top Layer, it is wrong to randomly route over the Bottom Layer
or other layers, which will affect the module's spurs and receiving sensitivity to varying degrees
;
It is assumed that there are devices with large electromagnetic interference around the module that will greatly
affect the performance. It is recommended to keep them away from the module according to the strength of the
interference. If necessary, appropriate isolation and shielding can be done
;
Assume that there are traces with large electromagnetic interference (high-frequency digital, high-frequency analog,
power traces) around the module that will greatly affect the performance of the module. It is recommended to stay
away from the module according to the strength of the interference.If necessary, appropriate isolation and shielding
can be done.