8.2 AT parameter analysis

When the serial port receives the correct command, the serial port will return "command=OK", otherwise it will
return "=ERR"

Command parameters

Parameter meaning

Baud ( serial port baud rate )

0:1200

1:2400

2:4800 3:9600

4:19200 5:38400 6 : 57600 7:115200

Parity ( serial port parity bit )

0:8N1

1:8O1

2:8E1

3:8N1

Rate (over-the-air data rate)

Applicable to 400MHz frequency band and 900MHz

frequency band

0:2.4K

1:2.4K

2:2.4K

3:4.8K

4:9.6K

5:19.2K

6:38.4K

7:62.5K

Rate (over-the-air data rate)

Applicable to 230MHz frequency band

0:2.4K

1:2.4K

2:2.4K

3:2.4K

4:4.8K

5: 9.6K

6:15.6K

7:15.6K

Packet (packet length)

0: 240

1: 128

2:64

3:32

Role (WOR role)

0: Receiving

1: Transmitting

Period (WOR period)

0:500ms

1:1000ms 2:1500ms 3:2000ms

4:2500ms 5:3000ms 6:3500ms 7:4000ms

Power (transmission power)

Note 1

0:22dBm

1:20dBm

2:17dBm

3:14dBm

Mode (transmission mode)

0: transparent

1: fixed point

Router (repeater mode)

0: Close

1: Open

AT+TRANS=?

Query sending mode

AT+TRANS=1

Return to fixed point mode

AT+ROUTER=?

Query relay mode

AT+ROUTER=1

Return to relay mode

AT+LBT=?

Query the Listen Before
Talk function switch

AT+LBT=1

Return LBT switch status

AT+ERSSI=?

Query the environmental
noise RSSI switch

AT+ERSSI=1

Return to environmental
noise switch status

AT+DRSSI=?

Query RSSI output

AT+DRSSI=1

Return channel RSSI
function is enabled

AT+ADDR=?

Query module address

AT+ADDR=1234

The return module address
is 1234

AT+CHANNEL=?

Query module working
channel

AT+CHANNEL=23

The return frequency is
433.125M

AT+NETID=?

Query network ID

AT+NETID=2

Return network ID is 2

AT+KEY=?

Query module key

Reading is not supported
(security considerations)

Return ERR

AT+DELAY=?

Query WOR delayed sleep
time

AT+DELAY=1000

Return to WOR delayed
sleep time is 1000ms

AT+SWITCH=?

Query software switching
mode switch

AT+SWITCH=0

Software switching mode is
off

AT+MODE=?

Query the current working
mode (can be queried in all
modes)

AT+MODE=0

Returns the current
transparent transmission
mode

Summary of Contents for E22 T22S Series

Page 1: ...gdu Ebyte Electronic Technology Co Ltd E22 xxxT22S series product user manual Copyright 2012 2024 Chengdu Ebyte Electronic Technology Co Ltd 1 E22 xxxT22S User Manual AT command 22dBm LoRa wireless mo...

Page 2: ...ing Address 11 5 5 Module Reset 11 5 6 Detailed explanation of AUX 11 5 6 1 Indication of Serial port data output 11 5 6 2 Indication of Wireless transmission 11 5 6 3 The module is being configured 1...

Page 3: ...2 Modules are easily damaged 28 12 3 BER Bit Error Rate is high 29 13 Welding Operation Guidance 29 13 1 Reflow soldering temperature 29 13 2 Reflow soldering curve 30 14 Related Models 30 15 Antenna...

Page 4: ...rights in estoppel or other ways whether express or implied The test data obtained in the article are all obtained by the Ebyte laboratory and the actual results may vary slightly We hereby declared...

Page 5: ...ctrum modulation technology it brings longer communication distance and stronger anti interference ability Supporting serial port upgrade of firmware making it more convenient to update firmware Suppo...

Page 6: ...ecurity alarm and remote keyless entry Smart home and industrial sensors etc Wireless alarm security system Building automation solutions Wireless industrial grade remote control healthcare products A...

Page 7: ...mption 22dBm Receiving current mA 15 15 17 Sleep current uA 3 3 3 Software shutdown temperature Operating temperature 40 85 Industrial grade design Storage temperature 40 85 Industrial grade design 2...

Page 8: ...l dimensions and pin definitions 3 1 E22 230 400 900T22S mechanical dimensions and pin definitions Pin number Pin name Pin direction Pin usage 1 NRST Input Module reset pin 3 3V 2 GND Module ground wi...

Page 9: ...t used 21 M1 Input very weak pull up Work with M0 to decide 4 working modes of the module cannot be left floating can be grounded if not used 22 RXD Input TTL serial port input connected to the extern...

Page 10: ...ction Description 5 1 Fixed point Transmission 5 2 Broadcast Transmission 5 3 Broadcasting Address For Example Set the address of module A to 0xFFFF and the channel to 0x04 When module A is used as a...

Page 11: ...r the module to work normally 5 6 Detailed explanation of AUX AUX Pin can be used as indication for wireless TX RX buffer and self check It can indicate whether there is data not transmitted via wirel...

Page 12: ...ondition is met AUX will outputs high level 2 When AUX outputs low level it means the module is busy it won t conduct working mode checking Within 1ms since AUX outputs high level the module working m...

Page 13: ...switching At this time the switching mode operation is invalid the module will process all the user data before performing the new mode detection Therefore the general recommendation is to detect the...

Page 14: ...can be received normally and the receiving function is equivalent to that in mode 0 6 4 Configuration mode Mode 2 type When M0 0 M1 1 the module works in mode 2 Transmitting Wireless transmission is t...

Page 15: ...ers E g 1 Read channel command starting address length parameter Send C1 05 01 Returen C1 05 01 09 E g 2 Read module address network address serial port and air data rate Send C1 00 04 Return C1 00 04...

Page 16: ...the data blocking and possible data loss caused by the same baud rate It is generally recommended that both communication parties have the same baud rate 0 0 0 Serial port baud rate 1200 0 0 1 Serial...

Page 17: ...are this bit will be turned off automatically If you don t want to use the M0 M1 pins to switch working modes you can enable this function and use specific serial port commands to switch modes Format...

Page 18: ...ke up can be modified The default time is 0 1 To modify the delay time after wake up WOR receiver needs to send the command C0 09 02 03 E8 in the configuration mode C0 is writing command 09 is the sta...

Page 19: ...munication parties have the same baud rate 0 0 0 Serial port baud rate 1200 0 0 1 Serial port baud rate 2400 0 1 0 Serial port baud rate 4800 0 1 1 Serial port baud rate 9600 default 1 0 0 Serial port...

Page 20: ...C2 C3 02 00 to switch to transparent transmission mode Send C0 C1 C2 C3 02 01 to switch to WOR mode Send C0 C1 C2 C3 02 02 to switch to configuration mode Send C0 C1 C2 C3 02 03 to switch to sleep mo...

Page 21: ...2 is the length 03 E8 is the set delay the maximum delay FFFF is 65535ms if the delay is set to 0 the wake up delay is turn off 2 Data can be sent within the delay 0 WOR receiver default Working in WO...

Page 22: ...ories command commands setting commands and query commands Users can query the AT command set supported by the module through AT HELP The baud rate used by the AT command is 9600 8N0 When the input pa...

Page 23: ...nnel Set module working channel AT CHANNEL 23 Set frequency to 433 125M AT NETID netid Set network ID AT NETID 2 Set network ID to 2 AT KEY key Set module key AT KEY 1234 Set the module key to 1234 AT...

Page 24: ...Note 1 0 22dBm 1 20dBm 2 17dBm 3 14dBm Mode transmission mode 0 transparent 1 fixed point Router repeater mode 0 Close 1 Open AT TRANS Query sending mode AT TRANS 1 Return to fixed point mode AT ROUTE...

Page 25: ...eed to keep Power on and wait 60 seconds the program will automatically exit otherwise it will enter the upgrade mode indefinitely even if it is restarted After entering the upgrade mode the baud rate...

Page 26: ...fore Repeater 2 can forward the data of Repeater 1 to the network NETID 05 Thus node 3 and node 4 can receive the data from node Node 4 outputs data normally but no ourput from Node3 because Node 3 ha...

Page 27: ...cimal 11 Hardware Design It is recommended to use a DC regulated power supply to power the module The power supply ripple coefficient should be as small as possible and the module must be reliably gro...

Page 28: ...f damage Try to stay away from some TTL protocols whose physical layer is also 2 4GHz such as USB3 0 The antenna installation structure has a great impact on module performance Make sure the antenna i...

Page 29: ...ply Poor quality or too long extension cords and feeders can also cause a high bit error rate 13 Welding Operation Guidance 13 1 Reflow soldering temperature Reflow soldering curve characteristics Lea...

Page 30: ...e mm Communication Interface E22 230T22S SX1262 230M 22 5 SMD 16 26 TTL E22 230T30S SX1262 230M 30 10 SMD 20 40 5 TTL E22 400T22S SX1262 433 470M 22 5 SMD 16 26 TTL E22 400T30S SX1262 433 470M 30 10 S...

Page 31: ...raight omnidirectional TX433 JZG 6 Rubber antenna 433M SMA J 2 5 62 Short straight omnidirectional TX433 JW 5 Rubber antenna 433M SMA J 2 0 50 Flexible omnidirectional TX433 JWG 7 Rubber antenna 433M...

Page 32: ...n Revision date Revision Notes Maintenance man 1 0 2023 6 15 initial version Hao About Us Technical support support cdebyte com Documents and RF Setting download link https www cdebyte com Thank you f...