Chengdu Ebyte Electronic Technology Co., Ltd. E220-400T30S User manual
Copyright ©2012–
2018
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
11
5.6.2 Indication of wireless transmitting
Buffer (empty): the internal 256 bytes data in the buffer are written to the RFIC (Auto sub-packaging). When
AUX=1, the user can input data less than 256 bytes continuously without overflow. Buffer (not empty): when AUX=0,
the internal 256 bytes data in the buffer have not been written to the RFIC completely. If the user starts to transmit data at
this circumstance, it may cause overtime when the module is waiting for the user data, or transmitting wireless sub
package. When AUX = 1, it does not mean that all the UART data of the module have been transmitted already, perhaps
the last packet of data is still in transmission.
5.6.3 Configuration procedure of module
⚫
Only happened when power-on resetting or exiting sleep mode
5.6.4 Notes for AUX
No.
Description
1
For function 1 & function 2 mentioned above, the priority should be given to the one with low level output, which means if it
meets each of any low level output condition, AUX outputs low level, if none of the low level condition is met, AUX outputs
high level.
2
When AUX outputs low level, it means the module is busy & cannot conduct operating mode checking. Within 1ms since AUX
outputs high level, the mode switch will be completed.
3
After switching to new operating mode, it will not work in the new mode immediately until AUX rising edge lasts for 2ms . If
AUX stays on the high level, the operating mode switch can be effected immediately.
Summary of Contents for E220-400T30S
Page 1: ...E220 400T30S User Manual ...