background image

Chengdu Ebyte Electronic Technology Co,;Ltd

                                                                                                     

      E32-170T30D user manual   

 

Copyright ©2012–2019

Chengdu Ebyte Electronic  Technology Co.,Ltd.

 

                                                                                                                                         

11 

 

 

If  the  module  switches  from  other  modes  to  stand-by  mode,  it  will  wo rk  in  stand-by  mode  only  after  all  the 

remained  data  process  completed.  The  feature  can  be  used  to save  power  consumption .  For  examp le,  when  the 

transmitter  wo rks  in  mode  0,  after  the  external  MCU  transmits  data  “12345”,  it  can  switch  to  sleep  mode 

immed iately  without  waiting  the  rising  edge  of  the  AUX  pin,  also  the  user’s  main  MCU  will  go  dormancy 

immed iately.  Then the  module  will transmit all the data through wireless transmission & go dormancy  1ms  later 

automatically,  which reduces MCU  working  time  & save power. 

 

Likewise, this feature can be used in any mode-switch. The module will start to work in new mode within 1ms  after 

completing  present  mode  task,  which  enables  the  user  to  omit  the  procedure  of  AUX  inquiry  and  switch  mode 

swiftly. For examp le,  when switching fro m transmitting  mode to receiving  mode, the user MCU can go dormancy 

before mode-switch,  using external  interrupt function to get AUX change so that the mode-switch can be realized. 

 

This operation is very flexib le and efficient. It is totally designed on the basis of the user MCU ’s convenience, at the 

same  time  the  work  load  and  power  consumption  of  the  whole  sys tem  have  been  reduced  and  the  efficiency  of 

whole system is largely improved. 

 

 

6.2

 

  Normal mode (mode 0) 

 

When M1  = 0 & M0  = 0, module  works in mode  0 

Transmitti

ng 

The module can receive the user data via serial port, and transmit wireless data package of 58 bytes. When the data 
inputted by user is up to 58 byte, the module will start wireless transmission. During which the user can input data 
continuously for transmission. 
When the required transmission bytes are less than 58 bytes, the module will wait 3-byte time and treat it as data 

termination  unless  continuous  data  inputted  by  user. Then  the  module  will  transmit  all  the  data through  wireless 
channel. 
When the module receives  the first data packet from user, the AUX outputs low level. 
After all the data are transmitted into RF chip and transmission start , AUX outputs high level. 
At this time,  it  means that the  last  wireless  data package  transmission  is  started,  which  enables  the  user to  input 

another  512  bytes  continuously.  The  data  package  transmitted  from  the  module  working  in  mode  0  can  only  be 
received  by the module working in mode 0 or 1. 

Receiving 

The wireless receiving function of the module is on, the data packet transmitted from the module working in mode 0 
& mode 1 can be received. 
After the data packet is received, the AUX outputs low level, 5ms later the module starts to transmit wireless data 
through serial port TXD pin.  
After all the wireless data have been transmitted via serial port, the AUX outputs high level. 

 

 

 

Summary of Contents for E32-170T30D

Page 1: ...E32 170T30D User Manual SX1278 170MHz 1W DIP Wireless Module ...

Page 2: ...1 FIXED TRANSMISSION 7 5 2 BROADCASTINGTRANSMISSION 7 5 6 1 Indication of UART output 8 5 6 2 Indication of wireless transmitting 9 5 6 3 Configuration procedure of module 9 5 6 4 Notes for AUX 10 6 OPERATING MODE 10 6 1 MODE SWITCH 10 6 2 NORMAL MODE MODE 0 11 6 3 WAKE UP MODE MODE 1 12 6 4 POWER SAVING MODE MODE 2 12 6 5 SLEEP MODE MODE 3 12 7 COMMAND FORMAT 13 7 1 DEFAULT PARAMETERS 13 7 2 READ...

Page 3: ...19 Chengdu Ebyte Electronic Technology Co Ltd 2 9 1 COMMUNICATION RANGE ISTOO SHORT 17 9 2 MODULE IS EASY TO DAMAGE 17 9 3 BER BIT ERROR RATE IS HIGH 18 10 PRODUCTION GUIDANCE 18 11 E32 SERIES 18 12 ANTENNA RECOMMENDATION 19 13 PACKAGE FOR BATCH ORDER 19 REVISION HISTORY 20 ABOUT US 20 ...

Page 4: ...It is in stable bulk production and are widely applied in utility meters IoT renovation smart home etc The modules feature data encryption and compression The data transmitted in air features randomness The encryption decryption algorithm makes data interception meaningless And the data compression enables shorter transmitting time and lower rate of being interfered which increased the reliability...

Page 5: ...e used in short distance Operating temperature 40 85 2 2 Operating parameter Main parameter performance Notes Min Typ Max Operating voltage V 3 3 5 0 5 2 5 0 V ensures output power Communication level V 3 3 For 5V TTL it may be at risk of burning down Operating temperature 40 85 Industrial design Operating frequency MHz 160 173 Support ISM band Power consumptio n Transmitting current mA 680 Instan...

Page 6: ... Ebyte Electronic Technology Co Ltd 5 antenna height 2 5m air data rate 2 4kbps TX length 58 Byte Maximum capacity of single package Buffer 512 Byte Modulation LoRa Communication interface TTL 3 3V Package DIP Connector 2 54mm Size 24 43mm Antenna SMA K 50 ohm impedance 3 Size and pin definition ...

Page 7: ...igured as open drain or pull up input 4 TXD Output TTLUART outputs connects to external RXD MCU PC input pin Can be configured as open drain or push pulloutput 5 AUX Output To indicate module s working status wakes up the external MCU During the procedure of self check initialization thepin outputs low level Can be configured as push pulloutput suspendingis allowed 6 VCC Input Power supply 2 3 5 2...

Page 8: ...er manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 7 5 Function description 5 1 Fixed transmission 5 2 Broadcasting transmission 5 3 Broadcasting address For example Set the address of module A as 0xFFFF or 0x0000 and the channel as 0x04 ...

Page 9: ...owered AUX outputs low level immediately conducts hardware self check and sets the operating mode based on user s parameters During the process the AUX remains low level After the process completed the AUX outputs high level and starts to work as per the operating mode combined by M1 and M0 Therefore users need to wait the AUX rising edge as the start of module s normal work 5 6 AUX description AU...

Page 10: ...ithout overflow Buffer not empty when AUX 0 the internal 512 bytes data in the buffer have not been written to the RFIC completely If the user starts to transmit data at this circumstance it may cause overtime when the module is waiting for the user data or transmitting wireless sub package When AUX 1 it does not mean that all the UART data of the module have been transmitted already perhaps the l...

Page 11: ...UART and wireless channel are open the only difference with mode 0 is that before transmitting data increasing the wake up code automatically so that it can awake thereceiver under mode 3 The receiver could be 0 1 or 2 2 Power saving 0 1 UART close wireless is under air awaken mode after receiving data UART open and send data transmitter must be mode 1 unable to transmit in this mode 3 Sleep 1 1 s...

Page 12: ... consumption of the whole sys tem have been reduced and the efficiency of whole systemis largely improved 6 2 Normal mode mode 0 When M1 0 M0 0 module works in mode 0 Transmitti ng The module can receive the user data via serial port and transmit wireless data package of 58 bytes When the data inputted by user is up to 58 byte the module will start wireless transmission During which the user can i...

Page 13: ...reless module monitors thepreamble code at regular time Once it gets the preamble code it will remain as receiving status and waiting for the completion of receiving the entire valid data package Then theAUX outputs low level 5ms later theserial port is open to transmit received wireless data through TXD Finally AUX outputs high level after process completed The wireless module stays in power savi...

Page 14: ...4 Three C3 are sent in hexadecimal format The module returns the version information and they must be sent in succession 7 1 Default parameters Default parameter values C0 00 00 1A 17 44 Model Frequency Address Channel Air data rate Baud rate Parity Transmitting power E32 170T30D 170MHz 0x0000 0x28 2 4kbps 9600 8N1 1W 7 2 Reading operating parameters Instruction format Description C1 C1 C1 In slee...

Page 15: ...s this frame data is control command Must be0xC0 or 0xC2 C0 Save theparameters when power down C2 Do not save theparameters when power down 1 ADDH High address byteof module the default 00H 00H FFH 2 ADDL Low address byteof module the default 00H 00H FFH 3 SPED 7 6 UART parity bit UART mode can be different between communication parties 0 0 8N1 default 0 1 8O1 1 0 8 E1 1 1 8N1 equal to 00 5 4 3 TT...

Page 16: ...ginal setting after complete the process 0 Transparent transmission mode 1 Fixed transmission mode 6 IO drive mode default 1 This bit is used to the module internal pull up resistor It also increases the level s adaptability in case of open drain But in some cases it may need external pull up resistor 1 TXD and AUX push pulloutputs RXD pull up inputs 0 TXD AUX open collector outputs RXD open colle...

Page 17: ...ll as possible and the module needs to be reliably grounded Please pay attention to the correct connection of the positive and negative poles of the power supply Reverse connection may cause permanent damage to the module Please check the power supply to ensure it is within the recommended voltage otherwise when it exceeds the maximum value the module will be permanently damaged Please check the s...

Page 18: ...he antenna is exposed preferably vertically upward When the module is mounted inside the case use a good antenna extension cable to extend the antenna to the outside The antenna must not be installed inside the metal case which will cause the transmission distance to be greatly weakened 9 FAQ 9 1 Communication range is too short The communication distance will be affected when obstacle exists Data...

Page 19: ...32 series Model No Core IC Frequency Hz Tx power dBm Distance km Air Data Rate Package Size mm Interface E32 868T20S SX1276 868M 20 3 0 3k 19 2k SMD 16 26 UART E32 915T20S SX1276 915M 20 3 0 3k 19 2k SMD 16 26 UART E32 400T20S SX1278 433M 470M 20 3 0 3k 19 2k SMD 16 26 UART E32 915T30S SX1276 915M 30 8 0 3k 19 2k SMD 25 40 3 UART E32 868T30S SX1276 868M 30 8 0 3k 19 2k SMD 25 40 3 UART E32 433T30S...

Page 20: ...y improve the communication system Therefore we recommend some antennas for wireless modules with excellent performance and reasonable price Model No Type Frequency Hz Interfa ce Gain dBi Height Cable Function feature TX170 XP 200 Sucker antenna 170M SMA J 4 200cm Sucker antenna High gain TX170 JK 20 Rubber antenna 170M SMA J 3 Flexible omnidirectional TX170 JK 11 Rubber antenna 170M SMA J 2 5 Fle...

Page 21: ... E32 915T20S E32 400T20S huaa 1 30 2018 01 22 Updating E32 868T20D E32 868T30D E32 915T20D E32 915T30D E32 170T30D huaa 1 40 2018 05 24 Updating antenna option huaa 1 50 2018 10 11 Manual dividing huaa About us Technical support support cdebyte com Documents and RF Setting download link www ebyte com Thank you for using Ebyte products Please contact us with any questions orsuggestions info cdebyte...