6. Instruction format
In sleep mode(mode 3:M1=1, M0=1), it supports below instructions on list.
(
Only support 9600 and 8N1 format when setting
)
C0 + 5 bytes working parameters are sent in hexadecimal format. 6 bytes in total and
( Save the parameters when power-down )
Three C1 are sent in hexadecimal format. The module returns the saved parameters and
C2 + 5 bytes working parameters are sent in hexadecimal format. 6 bytes in total and
must be sent in succession. ( Do not save the parameters when power-down )
Three C3 are sent in hexadecimal format. The module returns the version information
and they must be sent in succession.
Three C4 are sent in hexadecimal format. The module will reset one time and they must
Default parameter values
:
C0 00 00 1A 17 44
Model
Frequency
Address
Channel
Air data rate
Baud rate
Parity
Transmitting
power
E32-433T30S
433MHz
0x0000
0x17
2.4kbps
9600
8N1
1W