Chengdu Ebyte Electronic Technology Co,;Ltd E 70-433NW30S user manual
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co,;Ltd 16
2, Dormant Node
;
3, Sleep mode
;
4, (factory default), dial switch control
Example
:
AT+ WMCFG =4
Note: 1. After setting a new mode, it needs to be reset or power off and restart
5
AT+DINFO
Get facility information
AT+DINFO=ALLNODE
Description:
Query the short and long address of all node, and return by UART.
It works only when the device works in the coordinator mode
AT+DINFO=SELFS
Description:
Get short address and return by UART
AT+DINFO=SELFE
Description:
Get long address and return by UART
Example
:
AT+DINFO=SELFE
6
AT+ TFOCFG
Setting/Querying output format configuration (reboot valid)
AT+ TFOCFG=
?
Description:
Gets output format configuration
Response
:
TFOCFG:0
AT+ TFOCFG=Value
Description:
Value
:
0~7
0
:
Output: valid data (transparent transmission)
)
1: Output: Valid Data +Long Address
2
:
Output: Valid Data +Short Address
3
:
Output: Valid Data+RSSI
4
:
Output
:
Valid Data+Long Short Address
5
:
Output
:
Valid Data+Long RSSI
6
:
Output
:
Valid Data+Short RSSI
7
:
Output
:
Valid Data+Long Short RSSI
Example
:
AT+ TFCFG=0
7
AT+ TFICFG
Setting/Querying input transmission format configuration (reboot valid)
AT+ TFICFG=
?
Description:
Gets input transmission format configuration
Response
:
TFICFG:0
AT+ TFICFG=Value
Description: