Chengdu Ebyte Electronic Technology Co.,Ltd.
Copyright ©2012–2020
Chengdu Ebyte Electronic Technology Co.,Ltd.
31
transmission.
6
5
4
Wake-up time
This parameter is only valid for modes 4 and 6;
For mode 6, the wake-up time affects the WOR
period of
the
module and
has a large impact on
power consumption.
For mode 4
,
the wake-up time determines the
number of wake-up codes that the module increases
before launching, so as to ensure that the module in
mode 6 is effectively awakened;
Generally speaking, modes 4
and
6
need to be used
together, and the wake-up time set by both parties
must be consistent.
0
0
0
500ms
0
0
1
1000ms (default).
0
1
0
1500ms
0
1
1
2000ms
1
0
0
2500ms
1
0
1
3000ms
1
1
0
3500ms
1
1
1
4000ms
3
FEC switch (forward error correction).
After the FEC
is turned off, the actual
data
transmission rate is increased, but the
anti-interference ability is weakened, and the distance
is slightly closer, which is selected according to the
actual application;
Both parties to the communication must be on or off.
0
Turn off the FEC
1
Open FEC (default).
2
IO drive mode
This bit is used to enable the internal pull-up resistor
of the module;
Open-drain mode is more level adaptable, and
external pull-up resistors may be required in some
cases.
0
TXD
,
AUX open output, RXD open input
1
TXD
,
AUX push-pull output, RXD pull-up input
(default).
1
0
Transmit power
The external power supply must provide a current
output capability of more
than
80mA and ensure that
the power supply ripple is less than 100mV;
It is not recommended to use smaller power
transmission, and its power utilization efficiency is not
high.
0
0
14dBm (default).
0
1
10dBm
1
0
7dBm
1
1
4dBm
Give an example (the meaning of the ordinal number 3 "SPED" byte).
The binary bit of the byte
7
6
5
4
3
2
1
0
Specific value (user configuration)
0
0
0
1
1
0
0
0
Representative meaning
Serial port check
digit 8N1
The serial port baud rate is 9600
The air rate is 2.5k
Corresponds to hexadecimal
0
18
Chapter 8 Parameter Configuration
When the module is in mode 3
(M2, M1,
M0 = 011) or mode 5 (M2, M1
,
M0 = 101), you can configure the module