Long address transmission. When configured to long address transmission, the user must specify the long address
before sending data.
7.2 Normal node
If users configure the operating mode 4,
(
M0=0,M1=1
)
or users configure the operating mode as 1, the module
works in the normal node mode. In the normal node mode, the data can be received and sent in real time. It is suitable for
application with low power consumption but high real-time requirement.
7.3 Dormant node
If the user configures the operating mode as 4, M0=1,M1=0, or the user configures the operating mode as 2, the
module works in the dormant node mode, the device request if there is data transmitted by coordinator according to the
user-configured sleep period , The non-broadcast data sent by the coordinator will be temporarily stored inside the
coordinator. The device is in low power consumption during the sleep period. If the sleep node wants to send data
actively, the user should send no more than two bytes to wake up the device. After the byte data is used to wake up the
device and the wake-up byte is sent, the user needs to wait for more than 100ms to send the real data. After the wake-up
byte is sent, the user needs to wait for 100ms to send the real data and the wake-up data will be discarded. After the
device was waken up, the module will open the serial port, receiving AT command, if more than 2 seconds, there is no
data input, the module will close serial port and go to sleep.The sleep node is suitable for applications where the user
requires high power consumption but does not require high real-time data.
The input transmission format of the
coordinator cannot be broadcast mode when sending data to the sleeping node , instead, the AT + TFICFG = Value
command should be used to configure its input mode to short address or long address mode. Then
Communicate with the
sleeping node according to the usage of this AT command.
7.4 Configuration mode
When M0=1,M1=1,the device will switch to configuration mode. In the this mode, the serial port parameters are:
115200, 8N1, and the average operating current is 4uA. In this mode, the module cannot send and receive data. When the
external AT instruction is configured, needs the serial port to send no more than two bytes data to wake up the
device .After the wake-up byte is sent, the user needs to wait for 100ms to send the real data and the wake-up data will be
discarded. After the device was waken up, the module will open the serial port, receiving AT command, if more than 2
seconds, there is no data input, the module will close serial port and go to sleep. The next AT command requires the user
to resend the wake-up byte.
7.5 Mode switching
No
Remarks
1
By default, Users can decide the operating mode by the combination of M1 and M0
2
In any operating mode, users can configure the operating mode through the AT command, refer to AT command
description for details