Chengdu Ebyte Electronic Technology Co,;Ltd
E70-900TxxSx_user manual
Copyright ©2012–2023
,
Chengdu Ebyte Electronic Technology Co,;Ltd
5
Health care products
;
Advanced Meter Reading Architecture(AMI)
;
Automotive industry applications.
2. Specification and parameter
2.1 Limit parameter
Main parameter
Performance
Remark
Min.
Max.
Power supply
(
V
)
E70-900T30S
0
5.5
Voltage over 3.8V will cause permanent
damage to module
E70-900T14S/S2
0
3.8
Blocking power
(
dBm
)
E70-900T30S
-
30
Chances of burn is slim when modules
are used in short distance
E70-900T14S/S2
-
10
Operating temperature
(
℃
)
-40
85
-
2.2 Operating parameter
E70-900T30S
Main parameter
Performance
Remark
Min
Typ.
Max.
Operating voltage
(
V
)
2.2
3.3
5.5
≥3.3 V ensures output power
Communication level
(
V
)
-
3.3
-
For 5V TTL, it may be at risk of
burning down
Operating temperature
(
℃
)
-40
-
85
Industrial design
Operating frequency
(
MHz
)
861
-
922.5
Support ISM band
Power
consumptio
n
Transmitting current [mA]
-
610
-
Instant power consumption
Receiving current [mA]
-
14
-
-
Turn-off current [μA]
-
4
-
Software is shut down
Max Tx power
(
dBm
)
29.5
30
30.5
-
Receiving sensitivity
(
dBm
)
-109
-110
-111
Air data rate is 5kbps
Air data rate
(
bps
)
2.5k
2.5k
168k
Controlled via user’s programming
E70-900T14S/S2
Main parameter
Performance
Remark
Min
Typ.
Max.
Operating voltage
(
V
)
2.2
3.3
3.8
≥3.3 V ensures output power