Chengdu Ebyte Electronic Technology Co.,Ltd.
Copyright ©2012–2021
,成都亿佰特电子科技有限公司
6
16
DIO_12
Input/Output
General IO port (see CC26xx manual for details)
17
DIO_13
Input/Output
General IO port (see CC26xx manual for details)
18
DIO_14
Input/Output
General IO port (see CC26xx manual for details)
19
DIO_15
Input/Output
General IO port (see CC26xx manual for details)
20
JTAG_
TMS
Input/Output
JTAG_TMSC, High drive (see CC26xx manual for details)
21
JTAG_
TCK
Input/Output
JTAG_TCKC, High drive (see CC26xx manual for details)
22
DIO_16
Input/Output
High drive General IO port, JTAG_TDO (see CC26xx manual for details)
23
DIO_17
Input/Output
High drive General IO port, JTAG_TDI (see CC26xx manual for details)
24
DIO_18
Input/Output
General IO port (see CC26xx manual for details)
25
DIO_19
Input/Output
General IO port (see CC26xx manual for details)
26
DIO_20
Input/Output
General IO port (see CC26xx manual for details)
27
GND
-
Ground
28
DIO_21
Input/Output
Reset, low level (see CC26xx manual for details)
29
VDD
Power supply, 1.8V - 3.6V
30
DIO_22
Input/Output
Reset, low level (see CC26xx manual for details)
31
DIO_23
Input/Output
General IO port, sensor controller, Digital and analog (see CC26xx manual for details)
32
nRESE
T
Input
Reset, low level (see CC26xx manual for details)
33
DIO_24
Input/Output
General IO port, sensor controller, Digital and analog (see CC26xx manual for details)
34
DIO_25
Input/Output
General IO port, sensor controller, Digital and analog (see CC26xx manual for details)
35
DIO_26
Input/Output
General IO port, sensor controller, Digital and analog (see CC26xx manual for details)
36
DIO_27
Input/Output
General IO port, sensor controller, Digital and analog (see CC26xx manual for details)
37
DIO_28
Input/Output
General IO port, sensor controller, Digital and analog (see CC26xx manual for details)
38
DIO_29
Input/Output
General IO port, sensor controller, Digital and analog (see CC26xx manual for details)
39
DIO_30
Input/Output
General IO port, sensor controller, Digital and analog (see CC26xx manual for details)
40
、
41
、
42
GND
-
Ground
4 Basic operation
4.1 Hardware design
It is recommended to use a DC stabilized power supply. The power supply ripple factor is as small as possible and
the module needs to be reliably grounded;
Please pay attention to the correct connection of the positive and negative poles of the power supply,
reverse connection may cause permanent damage to the module;
Please check the power supply to ensure that between the recommended supply voltage, if exceeding the maximum,
the module will be permanently damaged;
Please check the stability of the power supply. Voltage can not fluctuate greatly and frequently;